the ground insulation of the cable (from coil connector or control unit connector), if not OK,
restore cable harness.
Coil 3 P0353
•
shorted to positive / shorted to negative, open circuit.
Error cause
•
If shorted to positive: excessive voltage has been detected at PIN 2 of the ENGINE con-
nector. If the circuit is open, shorted to negative: voltage equal to zero has been detected
at PIN 2 of the ENGINE connector.
Troubleshooting
•
If shorted to positive: disconnect the coil connector, set the key to ON, activate the coil with
Navigator and check voltage at connector PIN 2: if there is voltage, restore the cable har-
ness; if voltage = 0, replace the coil.
•
If the circuit is open, shorted to negative: check electric characteristics of the coil: if not OK,
replace the coil, if OK check the coil connector and the Marelli control unit connector; if not
OK, restore, if OK, check cable continuity between the two cable terminals: if there is not
continuity, restore the cable harness; if there is cable continuity, with key set to ON, check
the ground insulation of the cable (from coil connector or control unit connector), if not OK,
restore cable harness.
Coil 4 P0354
•
shorted to positive / shorted to negative, open circuit.
Error cause
•
If shorted to positive: excessive voltage has been detected at PIN 1 of the ENGINE con-
nector. If the circuit is open, shorted to negative: voltage equal to zero has been detected
at PIN 1 of the ENGINE connector.
Troubleshooting
•
If shorted to positive: disconnect the coil connector, set the key to ON, activate the coil with
Navigator and check voltage at connector PIN 1: if there is voltage, restore the cable har-
ness; if voltage = 0, replace the coil.
•
If the circuit is open, shorted to negative: check electric characteristics of the coil: if not OK,
replace the coil, if OK check the coil connector and the Marelli control unit connector; if not
OK, restore, if OK, check cable continuity between the two cable terminals: if there is not
continuity, restore the cable harness; if there is cable continuity, with key set to ON, check
the cable ground insulation (from coil connector or control unit connector), if not OK, restore
cable harness
RSV4 Factory a-PRC
Electrical system
ELE SYS - 201
Summary of Contents for RSV4 Factory a-PRC 2009
Page 1: ...SERVICE STATION MANUAL 898952 RSV4 Factory a PRC ...
Page 4: ......
Page 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Page 52: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS ...
Page 60: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Page 84: ...INDEX OF TOPICS TROUBLESHOOTING TROUBL ...
Page 94: ... 7 REPLACE THE STARTER BUTTON COMPONENT END Troubleshooting RSV4 Factory a PRC TROUBL 94 ...
Page 95: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Page 249: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Page 270: ...INDEX OF TOPICS ENGINE ENG ...
Page 387: ...INDEX OF TOPICS POWER SUPPLY P SUPP ...
Page 398: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Page 436: ...INDEX OF TOPICS CHASSIS CHAS ...
Page 460: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Page 472: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Page 483: ...INDEX OF TOPICS BODYWORK BODYW ...