14
15
INDOOR AIR QUAlITy FUNCTIONS
Humidity Control Screen for Humidification in Manual Mode
HUMIDITy CONTROl
(CONTINUED)
HUMIDIFIcaTIon sETPoInT
HUMIDIFIER aDJUsTMEnT
MANUAl MODE:
scREEn cycLEs REcoMMEnDED
HUMIDIFIcaTIon sETPoInTs
FOR VARIOUS OUTDOOR
TEMPERaTUREs
DONE BUTTON
(EXIT HUMIDITy conTRoL)
INDOOR AIR QUAlITy FUNCTIONS
HUMIDITy CONTROl
(CONTINUED)
If dehumidification is installed
the thermostat
can be configured, through the installer set-up, to
control dehumidification with either a whole home
dehumidifier or with the air conditioner (cooling unit) .
The thermostat will allow you to set the desired
humidity (% relative humidity) level in your home and
can be used to turn the dehumidification on or off.
Use the dehumidification adjustment to set the
dehumidification setpoint to 60% when first installed .
Allow dehumidification to run until the initial setpoint
is reached, before deciding if you want to change the
humidity setting .
Raise the setting if you prefer the air to be
less dry;
this will reduce the amount of time that
dehumidification runs .
lower the setting if you prefer the air to be
more dry;
this will increase the amount of time that
dehumidification runs .
your comfort is the best measure of how to adjust
your setting . When first installed, your dehumidifier
has to remove all the moisture that is initially in your
home . The home acts like a sponge so the moisture
in the materials of your home is at the same level
as the air . After drying the air, the materials of the
home will release the moisture back into the air until
they are again at the same level . As a result, it is
not uncommon for dehumidification to operate for an
extended period of time when it is first installed .