SPeCIfICaTIonS & DIMenSIonS
This humidifier is able to produce steam at various capacities depending on the voltage and current applied . The unit can be wired to use an
input voltage of 120, 208 or 240 Volts and input amperage can be set to 11 .5 or 16 .0 amps by changing a dip switch on the control circuit board
(see the Electrical Power Wiring & Shut Off Switch section on page 15) . Configure the unit appropriately for the application (see
Table 1
for
capacity specifications) .
Table 1 – Humidifier Capacities and Recommended Home Sizes
amperage
Voltage
Maximum steam
capacity (gal/day)
Maximum recommended home size in ft
2
*
Tight
average
loose
11 .5
120V
11 .5
2,500 sq ft
1,500 sq ft
1,000 sq ft
208V
20 .5
4,500 sq ft
2,500 sq ft
1,500 sq ft
240V
23 .3
16 .0
120V
16 .0
3,500 sq ft
2,000 sq ft
1,500 sq ft
208V
30 .0
6,000 sq ft
4,000 sq ft
2,500 sq ft
240V
34 .6
* Assumes 8 ft ceiling height, adjust as necessary for higher ceilings . For homes with multiple furnaces/air handlers a humidifier should be installed on each .
Model 800 Shipping weight:
28 lbs
Model 865 Shipping weight:
39 lbs
Humidifier operating weight:
23 lbs**
** As minerals precipitate unit weight can increase to approximately 30 lb .