BASIC OPERATION OF YOUR ZONED COMFORT CONTROL SYSTEM

Your Aprilaire Zoned Comfort System will allow you to increase your comfort by directing conditioned air to separate areas
(zones) based upon each zones thermostat setting. To operate the system, just set or program each zones thermostat to your
desired comfort and set-back settings.

When there is a heating or cooling call from any zone, the appropriate heating or cooling equipment will be turned on. The
dampers in zones not requiring heating or cooling will close and the conditioned air will be directed to the calling zone(s) until the
thermostat is satisfied.

Aprilaire Zoned Comfort Control is a heat call priority system. This means that there are certain times when heating calls will
take precedence over cooling calls. This occurs if two calls for opposing modes exist simultaneously while the system is idle, in
which case the heat call will be satisfied first. In all other cases a first-call, first-serve approach is taken satisfying the zone(s)
that call first. If, however, a call for opposing mode exists for a minimum of 20 minutes during equipment operation, the system
with shut down for an equipment protection minimum off time then changeover to satisfy the new call. The heating and cooling
equipment will not operate at the same time.

Your zone control system is designed to direct conditioned air only to the rooms served by that zone’s thermostat. However, due
to the open design of today’s homes, it may not be possible to maintain drastic temperature differences between zones. Closing
interior doors is a good way to reduce the air exchange between zones and increase the temperature difference between them.

The following sections describe how to make Heating, Cooling, and Emergency Heat calls as well as how your Aprilaire
Intelligent Zoned Comfort Control System can control the other pieces of your HVAC system.

HVAC CONTROL DETAILS

HEATING OPERATION (ALL MODELS OF EQUIPMENT)

To start heating:

1. Set your Model 8570 programmable thermostat to the Heat mode. This is accomplished by selecting HEAT from the 

Mode Menu. Consult the Model 8570 Owner’s Manual for details.

2. Adjust the thermostat set point to a temperature higher than the displayed room temperature, using the Up button, so that 

a Heat call is initiated. Again, consult your thermostat Owner’s Manual for details on how to do this properly.

The LED labeled “HEAT”, on the zone panel enclosure will indicate if the board is making a call for heat. If the equipment does
not come on right away, it may be due to the minimum-off time delay. Four minutes must elapse after the last heating cycle
before it can come on again. This built in feature ensures that the heating equipment does not cycle too frequently, shortening
the life of the equipment. 

71

˚

INFO

MENU

20

˚

OUTDOOR

03/31/04  8:32 AM

FAN AUTO

OFF

MAIN MENU

SET DATE AND TIME
HOLD
PROGRAM
FAN

SETTINGS

MODE - HEAT/COOL/ETC.

EXIT

SELECT

MODE MENU

OFF
AUTO

COOL
EMERGENCY HEAT

HEAT

BACK

SELECT

71

˚

INFO

MENU

20

˚

OUTDOOR

03/31/04  8:32 AM

 HEAT 70

SETPOINT

FAN AUTO

HEAT MODE

68

˚

RESUME

PROG.

MENU

20

˚

OUTDOOR

HOLD TIL 4:00PM

 HEAT 72

SETPOINT

HEATING

FAN ON

68

˚

INFO

MENU

20

˚

OUTDOOR

03/31/04  8:32 AM

 HEAT 68

SETPOINT

FAN AUTO

HEAT MODE

72

˚

HOLD THIS

TEMPERATURE

UNTIL 4:00PM

HEAT

BACK

SAVE

Summary of Contents for 6504

Page 1: ...Owner s Manual Model 6504 Includes Operating Instructions and Warranty Information Intelligent Zoned Comfort Control System READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...COMFORT CONTROL SYSTEM 6 HVAC CONTROL DETAILS Heating Operation 6 Cooling Operation 7 Emergency Heat Operation 7 Damper Operation 7 Fan Operation 7 ACCESSORY CONTROL DETAILS Electronic Air Cleaner Operation 8 Ventilation Control Operation 8 Humidifier Operation 9 INTELLIGENT SHARING OF INFORMATION 10 SYSTEM PRESSURE RELIEF 10 WARRANTY INFORMATION REGISTRATION 11 ...

Page 3: ...e controlled by the 6504 exclusively using the 8570 thermostats Aprilaire accessories such as humidifiers or air cleaners are controlled or share information through the 6504 DAMPERS Aprilaire dampers feature patented technology that eliminates the components most prone to failure with other manufacturers dampers gears These ultra reliable dampers are located in the systems supply duct work to dir...

Page 4: ...del 8570 Premium Programmable Thermostat Model 6504 Control Panel HVAC Equipment Aprilaire Automatic Humidifier Control Aprilaire Automatic Humidifier INTELLIGENT ZONED COMFORT CONTROL MODEL 6504 SYSTEM Aprilaire Model 5000 Electronic Air Cleaner Aprilaire Model 8100 Energy Recovery Ventilator or Model 8126 Ventilation Control Damper ...

Page 5: ...n ON Zone 4 Damper Closed FAN ON RED ON System Blower Operating OFF System Blower OFF VENT RED ON ERV or Ventilation Control Operating OFF ERV or Ventilation Control OFF EAC RED ON Electronic Air Cleaner Operating OFF Electronic Air Cleaner OFF HUM RED ON Humidifier Operating OFF Humidifier OFF HEAT RED ON Heating Equipment Operating OFF Heating Equipment OFF COOL RED ON Cooling Equipment Operatin...

Page 6: ...erences between zones Closing interior doors is a good way to reduce the air exchange between zones and increase the temperature difference between them The following sections describe how to make Heating Cooling and Emergency Heat calls as well as how your Aprilaire Intelligent Zoned Comfort Control System can control the other pieces of your HVAC system HVAC CONTROL DETAILS HEATING OPERATION ALL...

Page 7: ...for details Then by placing the thermostat s set point above the current temperature Emergency Heat will energize until the thermostat is satisfied If any other zone should call for heat during the Emergency Heat call it too will be satisfied by the Emergency Heat source NOTE Emergency Heat is generally much more expensive to operate than the Heat Pump Use only when necessary Your equipment may no...

Page 8: ...he amount of time that the ERV will operate or the Ventilation Damper will be open during the Vent Cycle Period VENT CYCLE Sets the period over which the amount of ventilation run time will be summed For example if the Vent Time is set for 30 minutes and the Vent Cycle is set for 1 hour the ERV or Ventilation Damper will be operated for 30 minutes per hour An Energy Recovery Ventilator ERV like th...

Page 9: ...on need has not been met If the AHC senses that humidification is still required when the heating system is about to turn off the Intelligent Zoned Comfort System will keep your fan operating until the need is met or for 15 minutes To prevent rapid cycling of your HVAC equipment the blower will be operated for no less than 5 minutes SECTION A SECTION B SECTION C 100 20 0 50 55 INDOOR RELATIVE HUMI...

Page 10: ... Owners Manual for details SYSTEM PRESSURE RELIEF With a Zone Control System some form of pressure relief must be designed into the system to assure proper operation and reduce the possibility of noise due to airflow The method of pressure relief that has been designed into your system could include use of a bypass damper or the Aprilaire method of controlled pressure relief With the controlled pr...

Page 11: ...FIVE YEAR PERIOD RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED THIS LIMITED WARRANTY IS VOID IF THIS UNIT IS NOT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR IF THE LIMITED WARRANTY IS VOID...

Page 12: ...prilaire products installed and serviced by qualified iHVAC contractors enhance your comfort health and energy efficiency Aprilaire Indoor Air Quality products with Engineered Simplicity Humidifiers Air Cleaners Dehumidifiers Electronic Thermostats Zoned Comfort Control Ventilation UV Germicidal Lamps P O BOX 1467 MADISON WI 53701 1467 PHONE 608 257 8801 FAX 608 257 4357 www aprilaire com 10006210...

Reviews: