TABLE 3 – Operation Guide

Condition

Solution

Condensation on windows.

Reduce the setting on the control dial
by 1 increment.

Lack of humidity.

Increase the setting on the control dial
by 1 increment. If the Humidifier Control
is already at the maximum setting of “7”,
set the Blower Activation Switch to
“ON”. The humidifier should be plumbed
to hot water when using the Blower
Activation feature.

Humidifier does not operate.

Turn dial to “Test/Reset”. Make certain
HVAC blower is operating. If unit still
does not operate, consult a heating
contractor.

Humidifier won’t shut off.

Turn dial to “Off”. If unit continues to
operate, consult a heating contractor.

Test mode.

System operation is checked by setting
the knob to “Test/Reset”. Make certain
HVAC blower is operating. Humidifier
will operate for one minute. NOTE:
Placing the knob in “Test/Reset” resets
the Water Panel change timer.

Red “Call Dealer for Service”
light flashes (

Figure A

).

Note the error code on the display (E1,
E2, E3 or E4) and call your heating and
air conditioning dealer.

Model 60 only:

Yellow “Change Water
Panel” light flashes 
(

Figure A

).

Refer to the Humidifier Owner’s
manual for instructions on changing
the Water Panel or call your heating
and air conditioning dealer for service.
After the Water Panel is replaced, turn
the Control knob to the “Test/Reset”
position until the green “Humidifier
On” light flashes, to reset the Water
Panel change timer.

Manual Humidifier Control

Figure C – Manual Humidifier Control

90-1237

Your Aprilaire humidifier is controlled by a Manual Humidifier
Control (see 

Figure C

). The Manual Humidifier Control is

installed either in the cold air return duct or on an interior wall of
the home. With the Manual Humidifier Control, it is important to
anticipate a drop in outdoor temperature and reduce the setting
accordingly to avoid excessive condensation, just as with the
Digital Humidifier Control installed in Manual Mode (see page 6).

To determine the indoor RH, slowly turn the knob clockwise and
counterclockwise and listen for 2 clicks. The indoor RH is within
the range of the 2 clicks.

Summary of Contents for 60

Page 1: ...Automatic Digital and Manual Humidifier Control Models 60 62 4655 Operating Instructions INSTALLER Please leave this Operation Manual with the homeowner ...

Page 2: ...C system has been idle for one hour the humidifier control will activate the HVAC system fan to sample the air for 3 minutes If the RH is lower than the set point the humidifier control will activate the humidifier and keep the fan running The humidifier will continue to operate for 2 hours or until the humidification set point is reached If the RH set point has not been reached by the end of a ca...

Page 3: ... needs to be set initially to match your home s condition Please follow these steps when adjusting your control refer to Figure A 1 Turn the dial setting knob to 5 which is within the normal range During the next 24 48 hours it may be necessary to adjust the dial for more or less humidity depending on your personal comfort and home s requirements Refer to TABLE 3 Operation Guide 2 During the colde...

Page 4: ...romise between humidity levels that would be most desirable for comfort and humidity levels that are suitable for protection of your home and to avoid condensation on your windows For example a wintertime indoor humidity of 50 may be considered ideal for comfort but unfortunately it probably would result in condensation which can cause damage to your home Observing the recommended humidity levels ...

Page 5: ...cked even if there is no call for humidity See Check the Humidifier Operation on page 12 ADDITIONAL INFORMATION Your humidifier is a precision system that will accurately maintain the humidity in your home For every 2 F change in outdoor temperature the Digital Humidifier Control will automatically adjust the indoor RH by 1 The Digital Humidifier Control will accurately control the humidity in you...

Page 6: ...error code on the display E1 E2 E3 or E4 and call your heating and air conditioning dealer Model 60 only Yellow Change Water Panel light flashes Figure A Refer to the Humidifier Owner s manual for instructions on changing the Water Panel or call your heating and air conditioning dealer for service After the Water Panel is replaced turn the Control knob to the Test Reset position until the green Hu...

Page 7: ...on after 1 minute the display will flash the software revision level e g r1 MANUAL HUMIDIFIER CONTROL Set the knob to the highest setting make sure that the water saddle valve is open and that there is electricity to the humidifier The HVAC system must be operating for the humidifier to function Confirm that the solenoid valve is energized and water is flowing into the humidifier Return control kn...

Page 8: ......

Page 9: ...P O Box 1467 Madison WI 53701 1467 Phone 800 334 6011 Fax 608 257 4357 www aprilaire com 10008993 8 13 B2205132B Printed in U S A 2013 Aprilaire A division of Research Products Corporation ...

Reviews: