Check the Humidifier Operation
DIGITAL HUMIDIFIER CONTROL
Set the knob to “Test/Reset”, make sure that the water saddle
valve is open and that there is electricity to the humidifier. The
HVAC fan must be running for the humidifier to function. NOTE:
Turning the knob to “Test/Reset” resets the “Change Water
Panel” timer. The humidifier will only operate for 1 minute in test
mode. (Model 400 and 400M: Floats must be down for the
solenoid valve to allow water flow.) Reduce the Humidifier
Control setting to the recommended inside humidity, depending
on the outside temperature.
DO NOT LEAVE IN TEST MODE
AS HUMIDIFIER WILL NOT OPERATE.
NOTE:
If the control knob is left in the test/reset position, after 1
minute the display will flash the software revision level e.g. r1.
MANUAL HUMIDIFIER CONTROL
Set the knob to the highest setting, make sure that the water
saddle valve is open and that there is electricity to the humidifier.
The HVAC system must be operating for the humidifier to
function. Confirm that the solenoid valve is energized and water is
flowing into the humidifier. Return control knob to desired setting.
Annual Summer Shutdown
Digital Humidifier Control in Automatic Mode (see
Figure A
)
and Blower Activation switch is in the ”OFF” position:
No adjustment is necessary.
Digital Humidifier Control in Automatic Mode (see
Figure A
)
and Blower Activation switch is in the ”ON” position:
Set the knob to the “OFF” position.
Digital Humidifier Control in Manual Mode (see
Figure B
):
Set the knob to the “OFF” position.
Manual Humidifier Control (see
Figure C
):
Set the knob to the “OFF” position.