lOCATION CONSIDERATIONS
TOP VIEW
FILTER
MINIMUM
CLEARANCE FOR FILTER
(EITHER SIDE)
20"
6" MINIMUM CLEARANCE
FOR PROPER AIR FLOW
ELECTRICAL SERVICE
ACCESS THIS SIDE
6 FT. POWER CORD
FIGURE 2 – Filter Access Clearance
90-2042
• Allow sufficient clearance for filter removal and
to prevent airflow obstruction
• Electrical service access will require the removal
of the side panel shown. Allow sufficient space
for service on this side of the unit.
• If locating the unit in an attic or crawl space, a
Model 76 Control mounted in the living space
is recommended. Refer to Model 76 Installation
Instructions and Owner’s Manual.
• Always install the dehumidifier in a condensate
pan when locating in or over a finished space.
CUT OFF
PLASTIC STRAP
REMOVE SHIPPING BRACKET
FIGURE 1 – Remove Shipping bracket
90-2040
IMPORTANT:
Cut the strap securing the compressor
shipping support bracket and remove the strap, shipping bracket
screws, and bracket. See
Figure 1
.
SET UP DEHUMIDIFIER FOR INSTAllATION
3