![Applied Motion Products STR2 Hardware Manual Download Page 9](http://html1.mh-extra.com/html/applied-motion-products/str2/str2_hardware-manual_2955247009.webp)
9
STR2 Hardware Manual
920-0059A
4/20/2012
If you plan to use a regulated power supply you may encounter a problem with regeneration.
If you rapidly decelerate a load from a high speed, much of the kinetic energy of that load is
transferred back to the power supply. This can trip the overvoltage protection of a switching
power supply, causing it to shut down. We offer the RC-050 “regeneration clamp” to solve this
problem. If in doubt, buy an RC-050 for your first installation. If the “regen” LED on the RC-050
never flashes, you don’t need the clamp.
RC-050 Regen Clamp
Power Supply and Ground Connections
Locate fuse in-line with “+” connection
regen LED