![Applied Motion Products STR2 Hardware Manual Download Page 38](http://html1.mh-extra.com/html/applied-motion-products/str2/str2_hardware-manual_2955247038.webp)
Alarm Codes
In the event of a drive fault or alarm, the green LED will flash one or two times, followed by a series of red flashes. The pat
-
tern repeats until the alarm is cleared.
404 Westridge Drive Watsonville, CA 95076
Tel (831) 761-6555 (800) 525-1609 Fax (831) 761-6544
www.applied-motion.com
Power and Motor Connector
Signal Connector
Connector Diagrams
Code
Error
solid green
no alarm, motor disabled
flashing green no alarm, motor enabled
1 green, 3 red over temperature
2 green, 3 red internal voltage out of range
1 green, 4 red power supply voltage too high
2 green, 4 red power supply voltage too low
1 green, 5 red over current / short circuit
1 green, 6 red open motor winding
V+ V
–
A
–
B+ B
–
A+
STEP DIR
EN
OUT
+
OUT
–
COM+