Installation and Service Manual – L Series Reverse Osmosis System – System Options Information
Systems and Components
Membranes
,
Filters
,
Chemicals
2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: [email protected]
Page 34
Copyright © 2008 Applied Membranes, Inc. All Rights Reserved.
Front Panel Controls and Indicator
Feature
Description
DISPLAY
Shows status of the system.
ALARM LAMP
Flashes when fault causes an RO system
shut-down. ON steady when a set-point
is exceeded that does not cause an RO
system shut-down.
POWER KEY
Places controller in operating or standby
mode.
LEFT ARROW KEY
Scrolls through set-points starting with
first set-point.
RIGHT ARROW KEY
Scrolls through set-points starting with
last set-point.
UP ARROW KEY
Increases value of set-point.
DOWN ARROW KEY
Decreases value of set-point
ENTER KEY
Confirms entry of new set-point value.
ALARM SILENCE/
RESET KEY
Push once for alarm silence and twice to
reset the system after a shut down has
occurred.
S150 Specifications
Power: 120/240 VAC -15+10%, 50/60Hz, 25Watts
Environment: -22°F to 140°F, 0-95% RH, non-condensing
Enclosure: 8" X 6" X 4" (203mm X 152mm X 102mm) NEMA 4X
Display: Alphanumeric backlit LCD
Front Panel: Overlay with LCD window, alarm lamp, 7 key
membrane switch
Relay Outputs:
RO pump relay 120/240VAC, 1HP
Inlet valve relay 120/240VAC, 5A
Flush valve relay 120/240VAC, 5A
Relays supply same output voltage as board power (120 or 240 VAC)
Cell:
TDS/Conductivity call with digital display, standard range, 0-
250ppm or µS. Other ranges available: 50, 100, 500, 1000, 2500,
5000. Wetted parts ABS and 316SS, ¾” NPT, 300 PSI max.
Optional I/O Expander:
Auxiliary/divert/boost relay
120/240VAC, 1HP
Divert/alarm relay
120/240VAC, 5A
Tank low switch input, dry contact