Connectors
Mains Input
200
– 250 VAC mains input. Connection details are supplied elsewhere in this manual.
Remote
Allows operator to remotely control CSP-P.
HV Output
4 pin proprietary connector. Using our HV2 plug, the large connector pins are proof tested to 6000
volts and can operate with current pulses up to 6000 amps. The two small pins are used as
interlock pins. If these are left open circuit, the CSP-P will not be able to enable the high voltage
(INTERLOCK fault).
Trigger Input
The trigger input is connected via a BNC socket.
Rear Panel
Fuses
The rear panel contains 2 fuse holders, and these are the only things we recommend the operator
checks if he has not received factory training. The fuses are rated as follows:-
F1
3A Antisurge 1¼"
(240V)
7A Antisurge 1¼"
(110V)
F2
3A Antisurge 1¼"
(240V)
7A Antisurge 1¼"
(110V)
Charge Rate Switch (see text).
Recommended position is OUT to make use of the AVIP circuitry.
Fan Filters
These filters should be periodically cleaned to ensure maximum air flow. This can be done with a
small stiff brush.