Appion WS260 Operation Manual Download Page 6

Getting Started

1. 

Remove the WS260 from its protective case and place on a level and firm surface. If the scale is 
used on a sloped or otherwise unstable surface, irregular or inaccurate readings may result.

2. 

Press the power button to turn on the WS260.

3. 

Take note of the reading on the display. If the reading does not show 

zero

 with an empty platform, 

you should ‘zero’ the scale to ensure an accurate reading. Press and hold the TARE button to zero 
the WS260.

4. 

With the scale properly zeroed, you may now weigh your materials.

5. 

If desired, connect to the Appion Central Mobile App to view remote readings, set alarms, 
download data and more.

Bluetooth® Wireless Operation

NOTE:

 Bluetooth® communication requires a compatible device running the Appion Central Mobile App. 

Visit the App Store or Google Play to download the latest version.

The WS260 is equipped with long range, low energy Bluetooth® technology. To connect to the 
WS260, simply open the Appion Central Mobile App and navigate to the ‘My Devices’ submenu. 
Bluetooth® connectivity is always enabled for ease of use and fast connections to your device. If 
desired, you can change the range (Normal or Long Range) in the main menu of the WS260. Note 
that changing to ‘Long Range’ will reduce battery life but enable up to ≈984ft (≈300m) line-of-sight 
connectivity.

Menu Items

MODE/RESOLUTION

Three resolution modes are available:

Normal:

 10g / 0.5 oz / 0.1 lb resolution - 

Ideal for most applications

High:

 1g 

(under 50kg)

/ 10g 

(over 50kg)

 - 

Ideal for critical charge applications

          0.1 oz / 0.01 lb 

(under 100lb)

, 0.5oz / 0.1 lb 

(over 100lb) 

Extended Battery Life:

 10g / 1 oz / 0.1 lb resolution - 

Up to 1200 hours battery life

 

CLEAR ALARMS

Clear any alarms that have been triggered. Alarms are set using the Appion Central Mobile App.

DISPLAY SETTINGS

Change 

Backlight Timeout & Brightness

Rotate Display 180º

, and toggle the 

Rate of Change

 view 

on the main display. 

DATA LOG

See 

Page 7

 for more information

BLUETOOTH® RANGE

Two ranges are available; 

Normal

 (≈328ft/100m) & 

Long Range

 (≈984ft/300m) - [line-of-sight]

ZERO SCALE

Zeroing the scale will clear the reading 

and

 store the weight of an 

empty

 platform.

CHANGE UNITS

The WS260 can display measurements in 

Kilograms

Kg

Pounds

Lb

Oz

Kg & g

Lb & Oz

WS260 OPERATION MANUAL

© 2019 APPION INC. - ALL RIGHTS RESERVED 

6

Summary of Contents for WS260

Page 1: ...COPYRIGHT 2019 APPION INC ALL RIGHTS RESERVED APPIONTM AND WS260TM ARE TRADEMARKS OF APPION INC WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT www AppionTools com ...

Page 2: ...to field service work Aluminum construction creates a lightweight reliable platform and combined with advanced electronics creates a scale that is highly versatile on the job From critical charges measured in grams to large systems with hundreds of pounds of refrigerant the WS260 has the ability to handle whatever the next jobsite holds The built in display allows standalone use or connect to the ...

Page 3: ...NAL PROTECTIVE EQUIPMENT AND MSDS WS260 OPERATION MANUAL 2019 APPION INC ALL RIGHTS RESERVED HAZARD RISK TO BREATHING ASPHYXIATION DANGER Air and refrigerants pumped during refrigerant recovery may pose certain breathing hazards WHAT CAN HAPPEN HOW TO PREVENT IT Refrigerant vapors may be harmful or toxic when inhaled Use only in well ventilated areas In enclosed areas mechanical ventilation should...

Page 4: ... rely on these switches to prevent overfilling Only a refrigerant scale can provide an active and accurate measurement of the amount of refrigerant in the storage container Do not rely on these switches to stop the flow of refrigerant into the container Only the valves on the recovery machine and on the cylinder can stop the flow of refrigerant into the container Refrigerant expands when heated Di...

Page 5: ...rom the system The Zero function is used to clear the reading and store the weight of an empty platform Example Technician has noted that the scale does not read 0 0 lbs when unladen on a flat level surface External Power A USB Type C cable sold separately may be used to power the WS260 in cases where battery power is not sufficient or long term use is desired Remove the protective rubber plug on ...

Page 6: ...ivity is always enabled for ease of use and fast connections to your device If desired you can change the range Normal or Long Range in the main menu of the WS260 Note that changing to Long Range will reduce battery life but enable up to 984ft 300m line of sight connectivity Menu Items MODE RESOLUTION Three resolution modes are available Normal 10g 0 5 oz 0 1 lb resolution Ideal for most applicati...

Page 7: ...cale will record data A shorter interval will result in a more detailed log Select from 1 5 10 30 60 second intervals ERASE Activating this option erases the current data log and removes the data log symbol from the main screen Appion Central unlocks the full potential of the WS260 and is available on the App Store and Google Play Search for Appion or visit www AppionTools com to download the late...

Page 8: ...ter 61 522 R 22 66 312 1 08 R 134a 67 46 1 10 R 404A 53 18 0 86 R 407C 62 28 1 01 R 410A 56 11 0 91 R 417A 62 383 1 01 R 417C 65 243 1 06 R 422A 58 343 0 95 R 422B 61 85 1 01 R 422C 59 174 0 96 R 422D 60 642 0 99 R 437A 65 231 1 06 R 438A 61 804 1 00 R 454B 51 343 0 83 Refrigerant recovery cylinders should only be filled to 80 of their maximum volume to allow for expansion during transportation Re...

Page 9: ...at the sight glass is in good condition and does not leak CAUTION Preparing for Fast Refrigerant Recovery Every recovery procedure starts with the same four basics Remove any access valve cores from the AC R System access fittings with a Valve Core Removal Tool This removes restrictions that would otherwise limit the performance of the recovery machine and or cause overheating of the recovery cyli...

Page 10: ...b Accuracy 5g 0 10Kg 5g 0 03 of Reading Resolution Normal 10g 0 5 oz 0 1 lb High 1g 0 1 oz 0 01 lb or 10g 0 5 oz 0 1 lb Extended Battery Life 10g 1 oz 0 1 lb Wireless Range up to 984ft 300m line of sight Durability Rating IP65 Battery Life 150 hours High Resolution to 1200 hours Extended Battery Life Units Pounds Lb Lb Oz Oz Kilograms Kg Kg g Power Source 3 AAA Batteries USB C Operating Temperatur...

Page 11: ...ce in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception wh...

Page 12: ...on Inc 2800 South Tejon St Englewood CO 80110 USA Tel 1 303 937 1580 Fax 1 303 937 1599 www AppionTools com Sales AppionTools com Support AppionTools com 2019 APPION INC ALL RIGHTS RESERVED OMXXXX EN 2019A ...