One-Year Factory Limited Warranty

 is provided on purchases of new equipment through authorized Appion product 

Dealers. Appion’s Factory Limited Warranty covers any failure due to defects in materials or workmanship occurring 
during the applicable warranty period and return shipping in the United States only. Only the original retail purchaser 
(herein referred to as the “End User”) is covered by this Factory Limited Warranty.

Requests for 

returns

 must be made through the Dealer where the item was purchased. Return policies vary by Dealer. 

‘Over-the-Counter’ exchanges

 must be approved by Appion within 90 days of purchase. Many common issues are 

easy to troubleshoot and solve. Call Appion at 303-937-1580 for troubleshooting.

  

Requests for Factory Warranty Services during the warranty period in the United States should be made directly to 
Appion Inc. 
To claim Factory Warranty Service, contact Appion by phone at 303-937-1580 or email at [email protected].

To receive the full One-Year Factory Limited Warranty, purchase only from authorized Appion sellers as identified on 
www.AppionTools.com. Purchases made through 

Unauthorized Dealers

 are done at the End User’s own risk and 

do not 

qualify

 for Appion’s Factory Limited Warranty.

Complete Warranty Information is available at www.AppionTools.com/Support

Factory Limited Warranty

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that 
may cause undesired operation.

Federal Communication Commission

Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement

This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be 
co-located or operating in conjunction with any other antenna or transmitter.

FCC Caution

To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could 
void the user’s authority to operate this equipment.

Industry Canada Radio Equipment

This device complies with Industry Canada licence-exempt RSS-210 standard. Operation is subject to the following two conditions: (1) 
this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired 
operation of the device.

 

Équipement radio d’Industrie Canada

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si 
le brouillage est susceptible d’en compromettre le fonctionnement.

Regulatory Information

WS260 OPERATION MANUAL

© 2019 APPION INC. - ALL RIGHTS RESERVED 

Summary of Contents for WS260

Page 1: ...COPYRIGHT 2019 APPION INC ALL RIGHTS RESERVED APPIONTM AND WS260TM ARE TRADEMARKS OF APPION INC WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT www AppionTools com ...

Page 2: ...to field service work Aluminum construction creates a lightweight reliable platform and combined with advanced electronics creates a scale that is highly versatile on the job From critical charges measured in grams to large systems with hundreds of pounds of refrigerant the WS260 has the ability to handle whatever the next jobsite holds The built in display allows standalone use or connect to the ...

Page 3: ...NAL PROTECTIVE EQUIPMENT AND MSDS WS260 OPERATION MANUAL 2019 APPION INC ALL RIGHTS RESERVED HAZARD RISK TO BREATHING ASPHYXIATION DANGER Air and refrigerants pumped during refrigerant recovery may pose certain breathing hazards WHAT CAN HAPPEN HOW TO PREVENT IT Refrigerant vapors may be harmful or toxic when inhaled Use only in well ventilated areas In enclosed areas mechanical ventilation should...

Page 4: ... rely on these switches to prevent overfilling Only a refrigerant scale can provide an active and accurate measurement of the amount of refrigerant in the storage container Do not rely on these switches to stop the flow of refrigerant into the container Only the valves on the recovery machine and on the cylinder can stop the flow of refrigerant into the container Refrigerant expands when heated Di...

Page 5: ...rom the system The Zero function is used to clear the reading and store the weight of an empty platform Example Technician has noted that the scale does not read 0 0 lbs when unladen on a flat level surface External Power A USB Type C cable sold separately may be used to power the WS260 in cases where battery power is not sufficient or long term use is desired Remove the protective rubber plug on ...

Page 6: ...ivity is always enabled for ease of use and fast connections to your device If desired you can change the range Normal or Long Range in the main menu of the WS260 Note that changing to Long Range will reduce battery life but enable up to 984ft 300m line of sight connectivity Menu Items MODE RESOLUTION Three resolution modes are available Normal 10g 0 5 oz 0 1 lb resolution Ideal for most applicati...

Page 7: ...cale will record data A shorter interval will result in a more detailed log Select from 1 5 10 30 60 second intervals ERASE Activating this option erases the current data log and removes the data log symbol from the main screen Appion Central unlocks the full potential of the WS260 and is available on the App Store and Google Play Search for Appion or visit www AppionTools com to download the late...

Page 8: ...ter 61 522 R 22 66 312 1 08 R 134a 67 46 1 10 R 404A 53 18 0 86 R 407C 62 28 1 01 R 410A 56 11 0 91 R 417A 62 383 1 01 R 417C 65 243 1 06 R 422A 58 343 0 95 R 422B 61 85 1 01 R 422C 59 174 0 96 R 422D 60 642 0 99 R 437A 65 231 1 06 R 438A 61 804 1 00 R 454B 51 343 0 83 Refrigerant recovery cylinders should only be filled to 80 of their maximum volume to allow for expansion during transportation Re...

Page 9: ...at the sight glass is in good condition and does not leak CAUTION Preparing for Fast Refrigerant Recovery Every recovery procedure starts with the same four basics Remove any access valve cores from the AC R System access fittings with a Valve Core Removal Tool This removes restrictions that would otherwise limit the performance of the recovery machine and or cause overheating of the recovery cyli...

Page 10: ...b Accuracy 5g 0 10Kg 5g 0 03 of Reading Resolution Normal 10g 0 5 oz 0 1 lb High 1g 0 1 oz 0 01 lb or 10g 0 5 oz 0 1 lb Extended Battery Life 10g 1 oz 0 1 lb Wireless Range up to 984ft 300m line of sight Durability Rating IP65 Battery Life 150 hours High Resolution to 1200 hours Extended Battery Life Units Pounds Lb Lb Oz Oz Kilograms Kg Kg g Power Source 3 AAA Batteries USB C Operating Temperatur...

Page 11: ...ce in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception wh...

Page 12: ...on Inc 2800 South Tejon St Englewood CO 80110 USA Tel 1 303 937 1580 Fax 1 303 937 1599 www AppionTools com Sales AppionTools com Support AppionTools com 2019 APPION INC ALL RIGHTS RESERVED OMXXXX EN 2019A ...

Reviews: