600840-000032 Stratus ESG Installation Instructions
Rev. 1.5
Last Revised: September 22, 2016
Page 18 of 47
Power requirements
Characteristic
Specification
Input Voltage Range
11 to 36 VDC
Nominal Current Draw
0.28 A at 28 VDC
0.5 A at 14 VDC
Power Input
8 W Typical
59.5 W Max
Table 8: Power requirements
1.9.
Required tools
The following tools are needed for installation of Stratus ESG.
Tool
Part Number
Used For
3/32” hex driver
Securing locking mechanism
through the faceplate
External retaining ring pliers
RF pass through adapter
Crimp tool
M22520/2-01
DSUB pins
Positioner
M22520/2-08
DSUB pins
Insertion/Extraction tool
M81969/39-01
DSUB pins
Table 9: Required tools
1.10.
Required hardware
The following parts are required for the installation of Stratus ESG.
Supplied parts:
Item
Appareo Part
Number
Commercial Part
Number
Quantity
Backplate
153510-000015
-
1
Transponder
153510-000017
-
1
Stratus ESG Rack
153540-000027
-
1
RF TNC Pass Through Adapter
251015-000077
-
1
RF BNC Pass Through Adapter
251015-000078
-
1
37 Pin DSUB Connector
251015-000074
M24308/2-4F
1
Screw
356060-000007
-
6
Strain Relief Backshell
356070-000006
M85049/48-1-4F
1
Table 10: Required hardware (supplied parts)