RoadRunner HD™ | High Definition Mobile Recorder
5
Alarm Connection
– J5, J6, J7, J10 and J4
AI 1 to 16 (Alarm-In)
: Use external devices to signal events to the Recorder. Mechanical or electrical switches can
be wired to the
AI
(Alarm-In) and
GND
(Ground) connectors. The voltage range is from 0V to 50V. When the electrical
switch is wired, the threshold voltage for NC (Normally Closed) is below 2.5V and for NO (Normally Open) is above
2.6V, and it should be stable at least 0.5 seconds to be detected.
GND (Ground)
: Connect the ground side of the Alarm input and/or alarm output to the GND connector.
NOTE: All the connectors marked GND are common.
NC 1 to 2 /NO 1 to 2 (Relay Alarm Outputs):
The Recorder can activate external devices such as buzzers or lights.
Connect the device to the
C
(Common) and
NC
(Normally Closed) or
C
and
NO
(Normally Open) connectors.
NC/NO
is a relay output which sinks 0.5A@125VAC and 1A@30VDC.
See
Chapter 3 ─ Configuration
for configuring alarm
output.
Connection
AI (1 to 16)
Alarm Inputs 1 to 16
GND
Chassis Ground
NC (1 to 2)
Relay Alarm Outputs 1 to 2
(Normally Closed)
NO (1 to 2)
Relay Alarm Outputs 1 to 2
(Normally Open)
C (1 to 2)
Relay Common 1 to 2
12V
VDC Output
Event Connection
– J5
Connection
LED 1
Heartbeat LED
LED 2
Recording Status LED
LED 3
Alarm Status LED
LED 4
Test LED
12V
VDC Output
GND
Chassis Ground
The Recorder can activate external LED devices. Heartbeat (
LED 1
), recording status (
LED 2
),
alarm status (
LED 3
) and test (
LED 4
) outputs are provided (50mA@12VDC).
LED 1:
The heartbeat LED blinks at a constant rate as long as the Recorder is operating
and stops blinking if the Recorder stops operating.
LED 2:
The recording status LED blinks when the Recorder is recording on the hard
disk drive.
LED 3:
The alarm status LED is lit when a configured alarm output is activated.
Summary of Contents for RoadRunner HD
Page 1: ......
Page 2: ......
Page 6: ...User Guide and Instruction Manual iv...