background image

3

CONVENTIONAL DETECTORS

ORBIS TABLE OF CONTENTS

Contact points for enquiries and help

  . . . . . . . . . . . . . .

2

Range of Products

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Features of Orbis®

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Choosing a detector: questions and answers

  . . . .

4

Orbis Optical Smoke Detector

  . . . . . . . . . . . . . . . . . . . . . . .

6

Where to use optical smoke detectors

  . . . . . . . . . . . . . . .

6

How does the Orbis optical detector work?

  . . . . . . . .

7

Environmental performance

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Technical Data

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Orbis Multisensor Smoke Detector

  . . . . . . . . . . . . . . . . .

8

Where to use multisensor smoke detectors

  . . . . . . . . .

8

How does the Orbis multisensor detector work?

 .

8

Environmental performance

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Technical Data

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

Orbis Heat Detector

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

Where to use heat detectors

  . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

Choosing the correct class of heat detector

  . . . . . . .

10

How do Orbis heat detectors work?

  . . . . . . . . . . . . . . . . .

11

Environmental performance

  . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

Technical Data

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

Orbis TimeSaver Base®

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

Installing Orbis

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

Fitting Orbis detector heads

  . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

Orbis Features—LED Status

  . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

TimeSaver LX

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Relay Base

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Sav-Wire Base

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Heater Base

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Orbis Adaptor

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Commissioning made easy

  . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

StartUp

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

What StartUp indicates

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

FasTest®

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

Smoke or Heat Testing

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

Maintenance and Servicing

  . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

DirtAlert

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

Approvals and Regulatory Compliance

  . . . . . . . . . . .

15

EU Directives

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

Assessed to ISO 9001: 2008

Certificate number 010

Information in this guide is given in good 

faith, but Apollo Fire Detectors cannot 

be held responsible for any omissions or 

errors.  The company reserves the right to 

change specifications of products at any 

time and without prior notice.

© Apollo Fire Detectors Limited 1999-2010

www.acornfiresecurity.com

www.acornfiresecurity.com

Summary of Contents for ORB-HT-11001-APO

Page 1: ...www apollo fire co uk ORBIS PRODUCT GUIDE Optical Detector Multisensor Detector Heat Detector Mounting Bases www acornfiresecurity com www acornfiresecurity com...

Page 2: ...ORBIS 2 conventional detectors from Apollo www acornfiresecurity com www acornfiresecurity com...

Page 3: ...etectors work 11 Environmental performance 11 Technical Data 11 Orbis TimeSaver Base 12 Installing Orbis 12 Fitting Orbis detector heads 13 Orbis Features LED Status 13 TimeSaver LX 14 Relay Base 14 S...

Page 4: ...f Orbis is to make installation commissioning and maintenance quicker enhance the reliability of detection and reduce the incidence of false alarms Orbis features TimeSaver Base designed for fast inst...

Page 5: ...st which is an m value of 2 The performance of Orbis detectors is given as a solid line which shows how evenly the optical detectors respond to the test fires If detectors respond too quickly the lowe...

Page 6: ...onfirmation of smoke before the alarm signal given The algorithms are used to verify signals from the sensing chamber to filter out transients and to decide when the detector should change to the alar...

Page 7: ...LED 1 2k connected to negative supply characteristic MECHANICAL Material Detector and base moulded in white polycarbonate Alarm Indicator Integral indicator with 360 visibility See Table 3 on page 13...

Page 8: ...ms The multisensor smoke detector has two sensors one for smoke one for heat and the alarm decision is derived from either sensor or a combination of both The multisensor is a development of the Orbis...

Page 9: ...ts 40mA Alarm load 600 Holding voltage 5 33V Minimum holding current 8mA Minimum voltage to light 5V alarm LED Alarm reset voltage 1V Alarm reset time 1 second Remote output LED 1 2k connected to nega...

Page 10: ...es heat detectors according to the highest ambient temperature in which they can safely be used without risk of false alarm The classes are identified by the letters A to G Class A is subdivided into...

Page 11: ...acteristics and the choice of the right type for a particular application may not always seem straightforward It is helpful to understand the way that heat detectors are classified as explained earlie...

Page 12: ...many installations bases with diodes are specified in order that an active end of line device may be fitted Diode bases are marked OD Loop continuity testing is facilitated as there is a continuity d...

Page 13: ...ors are wired in the correct polarity Flashes once per second No Flash FasTest Maintenance procedure takes just 4 seconds to functionally test and confirm detectors are functioning correctly Flashes o...

Page 14: ...Number ORB BA 10008 APO LED COM IN O U T 1 2 3 4 LED COM IN O U T 1 2 3 4 _ To next detector From control panel Screen Functional Earth Screen Functional Earth COM COM N C N C N O N O RELAY CONTROLLED...

Page 15: ...pplied to the detector If this is the case the LED will flash red once a second StartUp will not check whether the IN and OUT connections have been transposed This is not a problem if standard bases a...

Page 16: ...PP2147 2010 Issue 4 Apollo Fire Detectors Ltd 2003 2010 www acornfiresecurity com www acornfiresecurity com...

Reviews: