background image

 

10 

 

 

 

d.  Rinse the cup under warm running water until clean.  

  

 

e.  Fill the cup about ¼ full with water.  Reconnect Spray Gun to Air Hose.  Turn on the T100 Turbo Unit.  Direct 

the Spray Gun to a safe area and spray the clean warm water through the Spray Gun until the cup is empty. 
 

f. 

Turn off the T100 ™Turbo Unit. Disconnect the Spray Gun. Unscrew the cup.  
 

g.  Wipe all exposed areas dry.  

 

h.  Unscrew and remove the Air Cap Ring (#1). Rinse the threads under warm running water. Wipe, clean the 

threads and dry. Add a small amount of Spray Gun lube to the threads.   
 

i. 

Remove the Air Cap (#2). Rinse under warm running water. Wipe, clean and dry.  

j. 

If necessary, remove Air Distributor Plate (#5). Rinse under warm running water. Wipe clean, dry and 
lubricate with Spray Gun lube.  
 

k.  Reinstall the three pieces you just removed by reversing the removal procedure. Your Spray Gun should be        

ready for the next use. Store the Mist Applicator ™ in the holder on the T100 Turbo Unit.  

 
l. 

The Solution nozzle (#3) can be removed for additional cleaning if necessary. Be careful. There is a Solution        
nozzle gasket (#4) around the threads of the Solution nozzle. Be sure to reinstall or leakage will occur.        
Removal of the Solution nozzle is not necessary on a daily basis. You should however remove it once a        
week and rinse under running water. The Solution nozzle can be easily removed with an adjustable wrench        
or spanner. Place the tip of your adjustable wrench or spanner on the two flat areas of the nozzle and twist        
anti or counter clockwise.  

 
m.  The Solution needle (#8) can also be removed for additional maintenance. To remove: Turn the Solution        

Flow Screw anti or counter clockwise until it comes out of the Spray Gun. Be careful when removing the        
Solution Flow Screw as there is a small spring (#9) around the needle. Do not lose it. This is important to the        
operation of the Spray Gun. Set the spring aside and pull the trigger all the way back until you can grab the        
needle with your finger tips and pull it out from the back of the Spray Gun. Once removed, rinse under warm        
running water, Clean and dry. Reinstall reversing the removal procedure. NOTE: Occasionally it is necessary 
to lubricate the needle (#8) where it slides through the needle packing screw (#7). Simply rub a few drops of 
Spray Gun lube around the needle shaft and reinsert into the back of the Spray Gun.  

   
  

Troubleshooting 

 

 

 

 

Q1.  T100 Turbo unit turned ON. Air blows out of T6000 Spray Gun?  

A. This is correct. Air blows constantly when Turbo unit is ON.  

  

Q2.  T100 Turbo unit turned ON. Unit does not operate or blow air?  

A.  Check that the unit is plugged in to proper electric source. Be sure there is power at the electric       

source.  If there is no problem with electric supply, call for technical support.  

  

Q3. T100 Turbo unit is turned ON, the trigger is pulled back on Spray Gun, but no solution comes out?  

A1.  Check that the cup is screwed firmly to Spray Gun.  

Summary of Contents for Mini-Mist PRO

Page 1: ...uitable for Continuous Use DO NOT USE EQUIPMENT BEFORE READING THIS MANUAL This manual contains important warnings and instructions Please read these instructions carefully and keep for your reference...

Page 2: ...truction Manual Congratulations on purchasing the T100 Mini Mist Pro tanning system This product has been specially designed to provide an efficient application of tanning solution products Take a min...

Page 3: ...l ventilated Avoid all ignition sources such as static electricity sparks open flames hot objects sparks from connecting and disconnecting power cords and working light switches Follow the material an...

Page 4: ...THE WIRE WITH GREEN INSULATION WITH OR WITHOUT A YELLOW STRIPE IS THE GROUNDING WIRE 1 For any question regarding proper installation of the ground plug consult a qualified licensed or certified elect...

Page 5: ...not only damage your unit but also void your warranty 3 Next locate the male end of the air hose and connect it to the female quick connect on the T100 Mini Mist Pro tanning system a To insert the co...

Page 6: ...at Mist Applicator Patterns diagram below Note the position of the air cap and the direction of the spray pattern Pattern 1 is for spraying across from side to side Pattern 2 is for spraying up and d...

Page 7: ...away you hold the Spray Gun the more you will need to increase the solution flow thus causing abnormal amounts of airborne solution overspray f Holding the Spray Gun closer to the person being spraye...

Page 8: ...air hose is connected c Open the Solution Flow Knob as described in item 4 d Set the mist pattern you wish to use by adjusting the air cap to the desired position Refer to Mist Pattern Diagram e Dire...

Page 9: ...bs inward and pull the filter housing out Fig 1 Fig 2 c Pull the filter out of the filter housing to clean Fig 3 Fig 4 Fig 5 Air Filter Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 2 Air Hose a Wipe the air hose dai...

Page 10: ...with an adjustable wrench or spanner Place the tip of your adjustable wrench or spanner on the two flat areas of the nozzle and twist anti or counter clockwise m The Solution needle 8 can also be rem...

Page 11: ...nd not spring back Try spraying again If leaking continues the Needle packing needs to be replaced Rare Remove Solution needle packing screw 7 Pry out the Solution needle packing 4 Replace Reinstall N...