background image

 

 

 

 

Adjusting the Spray Gun 

 

 

 

a.  Locate the Solution Flow Knob (#10) on the T6000 diagram.  

b.  Turning the Solution Flow Knob clockwise reduces and will eventually stop the flow of solution. DO NOT        

over-tighten the screw as this will cause damage to the end of the needle. Once the trigger cannot be        
pulled back there is no point in tightening the screw down more, this will only damage the end of the        
needle.  

  
c.  Turning the Solution Flow Knob anti or counter clockwise will increase the flow of solution.  

d.  In general, 1 ½ - 2 full turn from the fully closed position will provide a good solution flow. You may find  

   

that you want more or less solution. You can adjust the Solution Flow Knob to your desired setting. 

NOTE:

 

Opening the Solution Flow Knob more than 3 turns will not increase the solution flow and will in fact 
decrease the efficiency of your Spray Gun.  
  

e.  In general, hold the T6000 Spray Gun 4” (10cm) from the person being sprayed. Moving the Spray Gun   

back will increase the size of the mist pattern. Moving the Spray Gun closer will decrease the size of the mist 
pattern. The further away you hold the Spray Gun, the more you will need to increase the solution flow thus 
causing abnormal amounts of airborne solution (overspray).  
  

f. 

Holding the Spray Gun closer to the person being sprayed along with a minimum flow of solution will provide 
the best results, no streaks or running solution and virtually no mist in the spray area.  
  

g.  Be sure to move the Spray Gun at a slow, steady speed keeping the distance of the Spray Gun the same 

through the entire application. This will ensure perfect results. It is actually very easy. Practice a few times 
and you will be an expert.  
  

h.  It is best to hold the Spray Gun in a vertical position when spraying. If you want to change the direction of the 

mist pattern, rotate the position of the air cap rather than turning the Spray Gun on its side.  
  

i. 

Always hold or store the Spray Gun in a vertical position. A slot in the T100 Turbo Unit is provided to hold 
and store the Spray Gun. It is a good habit to use it when you are not spraying.  
  
  

j. 

Do not over-tighten the solution flow screw (#10) as this will damage the end of the needle point. Tighten the 
screw until the needle cannot be pulled back. Once this point is reached there is no point in turning the 
solution slow screw anymore as this will only cause damage to the needle point.  

  
 

 
 

 

 
 
 
 
 

 

 

Summary of Contents for Mini-Mist PRO

Page 1: ...uitable for Continuous Use DO NOT USE EQUIPMENT BEFORE READING THIS MANUAL This manual contains important warnings and instructions Please read these instructions carefully and keep for your reference...

Page 2: ...truction Manual Congratulations on purchasing the T100 Mini Mist Pro tanning system This product has been specially designed to provide an efficient application of tanning solution products Take a min...

Page 3: ...l ventilated Avoid all ignition sources such as static electricity sparks open flames hot objects sparks from connecting and disconnecting power cords and working light switches Follow the material an...

Page 4: ...THE WIRE WITH GREEN INSULATION WITH OR WITHOUT A YELLOW STRIPE IS THE GROUNDING WIRE 1 For any question regarding proper installation of the ground plug consult a qualified licensed or certified elect...

Page 5: ...not only damage your unit but also void your warranty 3 Next locate the male end of the air hose and connect it to the female quick connect on the T100 Mini Mist Pro tanning system a To insert the co...

Page 6: ...at Mist Applicator Patterns diagram below Note the position of the air cap and the direction of the spray pattern Pattern 1 is for spraying across from side to side Pattern 2 is for spraying up and d...

Page 7: ...away you hold the Spray Gun the more you will need to increase the solution flow thus causing abnormal amounts of airborne solution overspray f Holding the Spray Gun closer to the person being spraye...

Page 8: ...air hose is connected c Open the Solution Flow Knob as described in item 4 d Set the mist pattern you wish to use by adjusting the air cap to the desired position Refer to Mist Pattern Diagram e Dire...

Page 9: ...bs inward and pull the filter housing out Fig 1 Fig 2 c Pull the filter out of the filter housing to clean Fig 3 Fig 4 Fig 5 Air Filter Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 2 Air Hose a Wipe the air hose dai...

Page 10: ...with an adjustable wrench or spanner Place the tip of your adjustable wrench or spanner on the two flat areas of the nozzle and twist anti or counter clockwise m The Solution needle 8 can also be rem...

Page 11: ...nd not spring back Try spraying again If leaking continues the Needle packing needs to be replaced Rare Remove Solution needle packing screw 7 Pry out the Solution needle packing 4 Replace Reinstall N...

Page 12: ...12 8 Diagram...

Page 13: ...ncluding but not limited to implied warranties of merchantability or fitness is excluded to the maximum extent permitted by law and if not excludable it is limited to the duration of the express Warra...

Reviews: