4
IM-291
KIT INSTALLATION (P/N 193-8033-1)
The following procedure and Figure 1 provides general installation instructions to
be used as an aid in installing Rack Mounting Kit (P/N 193-8033-1). These pro-
cedures will convert one bench mounted Model 8310 to an assembly that can be
installed easily in any cabinet or rack that is designed according to EIA RS-310
or MIL-STD-189.
a. Carefully position the attenuator unit with the top facing up and then
remove the two screws attaching the top cover to the chassis and
remove. Turn over and repeat for step to remove bottom cover.
b. If desired, remove the four plastic feet from bottom cover and discard.
NOTE
Panel Rack Adapter (2) can be installed on either right or left side of
instrument.
c. Align holes in Panel Rack Adapter (2) with holes in the desired side of
the Model 8310 and secure with two flat head screws (3) and
washers (5) as shown in Figu re 1.
d. Align the instrument right adapter ear (1) with Panel Rack Adapter (2)
as shown in Figure 1. Secure the Panel Rack Adapter (2) to the
adapter ear (1) using two flat head screws (4). Repeat step for left
side.
e. Re-install top and bottom covers and secure with previously removed
hardware.
f. Install the into cabinet or rack.
Downloaded from
Downloaded from
Downloaded from
Downloaded from