FLR Series
Rev. A5, 10/09
18
Automation Products Group, Inc.
APG...Providing tailored solutions for measurement applications
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]
8c. For “normally open” (NO) switching (code C switches), subtract 3 mm from
the measurement taken in step 7 and record the result. This distance will be
used to adjust the reed switch along the internal brass rod. The 3 mm is
subtracted to compensate for both the offset of the reed switch from the
actuation point (+3 mm), and the plug in the bottom of the stem (-6 mm). Refer
to drawings below.
Indention designates
top of float
For normally open (NO)
switching action, the center
point of reed switch is set 3 mm
above the desired actuation point.
ON
OFF
3 mm
9 mm
9 mm
Actuation
Point
Normally Open Switching for Code “C” Switches
Plug
Approx. 6 mm
Brass Rod