mPro400GC replaced by mPro400GCD
8
P2434JH | 2019-08
Apex Tool Group
3
EN
Procedure
Save parameters from mPro400GC-P/-M:
1. Select Navigator >
Administration > Save parameters
.
→ The
Save parameters
dialog opens.
2. Select the storage location and confirm with <OK>. The parameters can be stored on an internal stor-
age device (CF card) or an connected USB drive.
3. Press <All> to save all parameters.
4. Disconnect mPro400GC-P/-M and connect mPro400GCD-P/-M.
Set up mPro400GCD-P/-M:
1. Use cable 544196-XXX to connect mPro400GCD-P/-M and mPro400GC-S. See documentation
P2300HW or P2309HW.Use following inputs and outputs:
-
mPro400GCD-P/-M: output X22
-
mPro400GC-S: input X31
1. Use cable 544196-XXX to connect additional mPro400GC-S to the previous mPro400GC-S if neces-
sary. Use following inputs and outputs:
-
Previous mPro400GC-S: output X32
-
Following mPro400GC-S: input X31
2. Connect the System Bus Terminator 544197PT
to X32 at the
last mPro400GC-S.
3. Start mPro400GCD-P/-M.
4. Ensure that hybrid-capable software is used. The software has to be S168813-1.8.0 or newer.
5. Ensure that the current version of the operating system is used. The operating system has to be 2.7 or
newer.
Load parameters from an internal storage device (CF card) or a connected USB drive to
mPro400GCD-P/-M:
1. If the parameters have been saved on the CF card, insert the old CF card into mPro400GCD-P/-M. If
the parameters have been saved on the USB drive, insert the USB drive into mPro400GCD-P/-M.
2. Select Navigator >
Administration > Load parameters
.
→ The
Load parameters
dialog opens.
3. Select the previously saved parameters and confirm with <OK>.
4. Press <All> to load all parameters.
Adjust Programmable I/O Mapping:
1. Select Navigator > Tool Setup > I/O.
2. Confirm the messages with <Run it> and <Continue>.
→ The
Programmable I/O Mapping
dialog opens.
3. Re-parameterize the start switch and the tool light. All signals from PM_DIDO have to be changed to
TM_DIDO.
4. Confirm the change with <OK> and <Accept>.
Signal
Input/Output
PM_DIDO
Bit
TM_DIDO
Bit
Tool Group Start (SA)
Input
0
0
Reverse (TM_LL)
Input
1
1
Function button 2
Input
-
6
Status (Yellow LED)
Output
4
4
Tool OK 1 (Green LED)
Output
3
3
Tool NOK 1 (Red LED)
Output
2
2
Blue LED
Output
-
5
Summary of Contents for Cleco mPro4000GC