mPro400GC replaced by mPro400GCD
10
P2434JH | 2019-08
Apex Tool Group
3
EN
Set up mPro400GC-P/-M:
1. Use cable S981511 to connect mPro400GC-P/-M and mPro400GCD-S(H). See documentation
P2174HW. Use following inputs and outputs:
-
mPro400GC-P/-M: output X21
-
mPro400GCD-S(H): input X22 (TSnet in)
2. Use cable 962037-XXX to connect additional mPro400GCD-S(H) to the previous mPro400GCD-S(H) if
necessary. Use following inputs and outputs:
-
Previous mPro400GCD-S(H): output X21 (TSnet out)
-
Following mPro400GCD-S(H): input X22 (TSnet in)
3. Start mPro400GC-P/-M.
4.
Ensure that hybrid-capable software is used. The software has to be S168813-1.8.0
or newer.
5. Ensure that the current version of the operating system is used. The operating system has to be 2.7 or
newer.
Install Secondary controllers:
1. Select
Navigator > Tool Setup > Install
.
→ The
Assign Tool
dialog opens.
2. The following settings are required:
3. Confirm with <OK>.
The TSnet cable may not be connected to the infrastructure network.
Home network
mPro400GC-P/
mPro400GC-M
mPro400GCD-S(H)
Parameter
Description
Group Name
Select tool group. It is possible to select up to 16 tool groups.
Name
Assign a name to the Secondary.
Type
Select
Secondary
.
Summary of Contents for Cleco mPro4000GC