Apex Tool Group
P2434JH | 2019-08
7
mPro400GC replaced by mPro400GCD
3
EN
Adjust Programmable I/O Mapping:
1. Select Navigator > Tool Setup > I/O.
2. Confirm the messages with <Run it> and <Continue>.
→ The
Programmable I/O Mapping
dialog opens.
3. Re-parameterize the start switch and the tool light. All signals from PM_DIDO have to be changed to
TM_DIDO.
4. Confirm the change with <OK> and <Accept>.
3.2
Primary/Master controller with existing Secondary controllers
Scenario
•
mPro400GC-P/-M is replaced by mPro400GCD-P/-M.
•
Existing mPro400GC-S used.
Conditions for new system layout
Signal
Input/Output
PM_DIDO
Bit
TM_DIDO
Bit
Tool Group Start (SA)
Input
0
0
Reverse (TM_LL)
Input
1
1
Function button 2
Input
-
6
Status (Yellow LED)
Output
4
4
Tool OK 1 (Green LED)
Output
3
3
Tool NOK 1 (Red LED)
Output
2
2
Blue LED
Output
-
5
Old system layout
New system layout
Fig. 3-3: Primary/Master controller mPro400GC
with Secondary controller mPro400GC
Fig. 3-4: Primary/Master controller mPro400GCD
with Secondary controller mPro400GC
Type
Indication
Software version
mPro400GCD-P/-M: S168813-1.8.0 or newer.
mPro400GC-S:
S168025-510
Operating system
2.7
Cables
mPro400GCD-P/-M to mPro400GC-S.
System Bus Cable: Part number 544196-XXX
System Bus Terminator
Only required for mPro400GC-S: Part number 544197PT
mPro400GC-P/
mPro400GC-M
mPro400GC-S
mPro400GC-S
544196-XXX
544196-XXX
X21
X31
X32
X31
Arcnet
Arcnet
mPro400GCD-P/
mPro400GCD-M
mPro400GC-S
mPro400GC-S
544196-XXX
544196-XXX
544196-XXX
X22
X31
X32
X31
X32