For additional product information visit our website at www.ClecoTools.com
Installation
Instructions
P2434JH
2019-08
mPro400GC(D)
Integrating mPro400GC and mPro400GCD
Page 1: ...For additional product information visit our website at www ClecoTools com Installation Instructions P2434JH 2019 08 mPro400GC D Integrating mPro400GC and mPro400GCD ...
Page 2: ...dable language or transmitted on electronic mechanical optical or other media without the express permission of the Apex Tool Group Disclaimer Apex Tool Group reserves the right to modify supplement or improve this document or the product without prior notice Trademark Cleco is a registered trademark of Apex Brands Inc Apex Tool Group GmbH Industriestraße 1 73463 Westhausen Germany ...
Page 3: ...condary controllers 7 3 3 Primary Master controller with new Secondary controllers 9 3 4 Install Primary Master controller with Secondary controllers mPro400GC 11 3 5 Install Primary Master controller with Secondary controllers mPro400GCD 11 3 6 Primary Master controller with two types of Secondary controllers 13 3 7 Primary Master controller with Secondary controllers and Stack Lights 15 3 7 1 mP...
Page 4: ...he safety instructions listed in the respective hardware descriptions Number Name P2280PM Programming Manual mPro400GC D P2300HW Hardware Description mPro400GCD P P2349HW Hardware Description mPro400GCD S H P2309HW Hardware Description mPro400GCD M P2174HW Hardware Description mPro400GC italic Menu options e g Diagnostics input fields check boxes radio buttons or dropdown menus Indicates selection...
Page 5: ...D P Master mPro400GC M mPro400GCD M Secondary mPro400GC S mPro400GCD S H Fig 2 1 Primary Master controller mPro400GC P Fig 2 2 Primary Master controller mPro400GCD P Feature mPro400GC mPro400GCD P M mPro400GCD S H TSnet connection No Yes Yes ArcNet System Bus connec tion Connection to mPro400GC S BTS spindles System Bus Accessories socket trays stack lights I O boxes Yes Yes No TSnet connection Co...
Page 6: ... P2300HW or P2309HW Set up mPro400GCD P M 1 Start mPro400GCD P M 2 Ensure that hybrid capable software is used The software has to be S168813 1 8 0 or newer 3 Ensure that the current version of the operating system is used The operating system has to be 2 7 or newer Load parameters from an internal storage device CF card or a connected USB drive to mPro400GCD P M 1 If the parameters have been save...
Page 7: ...rse TM_LL Input 1 1 Function button 2 Input 6 Status Yellow LED Output 4 4 Tool OK 1 Green LED Output 3 3 Tool NOK 1 Red LED Output 2 2 Blue LED Output 5 Old system layout New system layout Fig 3 3 Primary Master controller mPro400GC with Secondary controller mPro400GC Fig 3 4 Primary Master controller mPro400GCD with Secondary controller mPro400GC Type Indication Software version mPro400GCD P M S...
Page 8: ...are is used The software has to be S168813 1 8 0 or newer 5 Ensure that the current version of the operating system is used The operating system has to be 2 7 or newer Load parameters from an internal storage device CF card or a connected USB drive to mPro400GCD P M 1 If the parameters have been saved on the CF card insert the old CF card into mPro400GCD P M If the parameters have been saved on th...
Page 9: ...layout New system layout Fig 3 5 Primary Master controller mPro400GC Fig 3 6 Primary Master controller mPro400GC with Secondary controller mPro400GCD Type Indication Software version mPro400GC P M S168813 1 8 0 or newer mPro400GCD S H S168025 510 Operating system 2 7 Cables mPro400GC P M to mPro400GCD S H RJ45 to TSnet Cable Part number S981511 XX mPro400GCD S H to mPro400GCD S H TSnet Cable Part ...
Page 10: ...GCD S H input X22 TSnet in 3 Start mPro400GC P M 4 Ensure that hybrid capable software is used The software has to be S168813 1 8 0 or newer 5 Ensure that the current version of the operating system is used The operating system has to be 2 7 or newer Install Secondary controllers 1 Select Navigator Tool Setup Install The Assign Tool dialog opens 2 The following settings are required 3 Confirm with...
Page 11: ...em layout Old system layout New system layout Fig 3 8 Primary Master controller mPro400GCD with Secondary controller mPro400GC mPro400GCD P mPro400GCD M mPro400GC S mPro400GC S 544196 XXX 544196 XXX X22 X31 X32 X31 X32 544197PT Arcnet Old system layout New system layout Fig 3 9 Primary Master controller mPro400GCD with Secondary controller mPro400GCD Type Indication Software version mPro400GCD P M...
Page 12: ...mPro400GC S input X21 3 Start mPro400GCD P M 4 Ensure that hybrid capable software is used The software has to be S168813 1 8 0 or newer 5 Ensure that the current version of the operating system is used The operating system has to be 2 7 or newer Install Secondary controllers 1 Select Navigator Tool Setup Install The Assign Tool dialog opens 2 The following settings are required 3 Confirm with OK ...
Page 13: ... mPro400GC S Use following inputs and outputs mPro400GCD P M output X22 mPro400GC S input X31 Old system layout New system layout Fig 3 10 Primary Master controller mPro400GCD with Secondary controller mPro400GC and mPro400GCD Type Indication Software version mPro400GCD P M S168813 1 8 0 or newer mPro400GCD S S168025 510 Operating system 2 7 Cables mPro400GCD P M to mPro400GCD S H TSnet Cable Part...
Page 14: ...S H output X21 Following mPro400GCD S H input X22 6 Start mPro400GCD P M 7 Ensure that hybrid capable software is used The software has to be S168813 1 8 0 or newer 8 Ensure that the current version of the operating system is used The operating system has to be 2 7 or newer Install Secondary controllers 1 Select Navigator Tool Setup Install The Assign Tool dialog opens 2 The following settings are...
Page 15: ...ts Stack light output Arcnet out mPro400GC S input X31 3 Use cable 544196 XXX to connect additional mPro400GC S or stack lights 4 Connect the System Bus Terminator 544197PT to the output at the last stack light 5 Start mPro400GC P M 6 Ensure that hybrid capable software is used The software has to be S168813 1 8 0 or newer 7 Ensure that the current version of the operating system is used The opera...
Page 16: ...rameterize the inputs and outputs of the stack lights Fig 3 12 Programmable I O Mapping The inputs are from bit 0 7 the outputs are from bit 8 15 For more information see ON OUTPUTS A OK BRIDGE in the supplied BUILDING PLAN of the stack lights 4 Leave the I O to save the settings The two rotary controls are named LOW and HIGH The Arcnet address consists of three digits Digit 1 fixed value 1 Digit ...
Page 17: ...ter 3 5 Install Primary Master controller with Secondary controllers mPro400GCD page 11 5 Start mPro400GC P M 6 Ensure that hybrid capable software is used The software has to be S168813 1 8 0 or newer 7 Ensure that the current version of the operating system is used The operating system has to be 2 7 or newer Type Indication Software version mPro400GCD P M S168813 1 8 0 or newer mPro400GCD S S168...
Page 18: ...rameterize the inputs and outputs of the stack lights Fig 3 14 Programmable I O Mapping The inputs are from bit 0 7 the outputs are from bit 8 15 For more information see ON OUTPUTS A OK BRIDGE in the supplied BUILDING PLAN of the stack lights 4 Leave the I O to save the settings The two rotary controls are named LOW and HIGH The Arcnet address consists of three digits Digit 1 fixed value 1 Digit ...
Page 19: ......
Page 20: ...ex Tool Group GmbH C O Spline Gauges Piccadilly Tamworth Staffordshire B78 2ER United Kingdom Phone 44 1827 8727 71 Fax 44 1827 8741 28 FRANCE Apex Tool Group SAS 25 Avenue Maurice Chevalier ZI 77330 Ozoir La Ferrière France Phone 33 1 64 43 22 00 Fax 33 1 64 43 17 17 GERMANY Apex Tool Group GmbH Industriestraße 1 73463 Westhausen Germany Phone 49 0 73 63 81 0 Fax 49 0 73 63 81 222 HUNGARY Apex To...