ATTENTION

 

Ը

Never use the product when it’s freezing cold. Let it warm to room temperature before using.

1. What’s in the Kit................................................................................................................................. 3
2. Keypad Functions ............................................................................................................................. 3
3. Preparation before Use ..................................................................................................................... 4
4. pH Calibration ...................................................................................................................................4
5. pH Measurement ............................................................................................................................... 5
6. Probe Cleaning .................................................................................................................................. 6
7. Probe Storage .................................................................................................................................... 6
8. Parameter Settings ........................................................................................................................... 6
9. ORP Measurement ............................................................................................................................ 7
10. Technical Specifications ................................................................................................................. 8
11. Other Specifications ........................................................................................................................ 8
12. Probe Replacement ......................................................................................................................... 9
13. Notes ............................................................................................................................................... 9
14. Battery Replacement ......................................................................................................................10
15. Troubleshooting Guide ................................................................................................................... 11
16. Warranty .........................................................................................................................................12

Thank you for purchasing Apera Instruments PH60S Premium Spear pH Tester. Please read this 
manual before use in order to properly use and maintain the product. 

For video tutorials, please go to support.aperainst.com

Summary of Contents for PH60S

Page 1: ...1 Premium Series PH60S Spear pH Tester pH mV Temperature User Manual IP67 ISO 9001 2015 APERA INSTRUMENTS LLC aperainst com...

Page 2: ...aning 6 7 Probe Storage 6 8 Parameter Settings 6 9 ORP Measurement 7 10 Technical Specifications 8 11 Other Specifications 8 12 Probe Replacement 9 13 Notes 9 14 Battery Replacement 10 15 Troubleshoot...

Page 3: ...hort press to cancel calibration 1 In measurement mode short press to switch between pH and mV 2 In settings short press to change parameters Unidirectional 1 Long press to enter calibration mode 2 In...

Page 4: ...pH 7 00 buffer solution first and make a quick stir in the solution then hold still 4 1 4 Long press to enter calibration mode screen will turn green Short press if you decide to quit calibration and...

Page 5: ...quirement 0 1 pH 2 pt Option A 1st pt 7 00 pH 2nd pt 4 00 pH or 1 68 pH Option A 1st pt 6 86 pH 2nd pt 4 01 pH or 1 68 pH Range 7 00 pH Option B 1st pt 7 00 pH 2nd pt 10 01 pH or 12 45 pH Option B 1st...

Page 6: ...y could damage the pH probe Pure water is only for rinsing the probe 5 5 Pure Water pH Measurement When testing pure water like tap water drinking water RO water or distilled water it will take longer...

Page 7: ...on screen screen turns red 8 3 3 Automatic Lock P4 Select On to activate auto lock function When reading is stable for more than 10 seconds the tester will lock the value automatically and HOLD icon w...

Page 8: ...mp Measuring Range 0 50 C 32 122 F Resolution 0 1 C Accuracy 0 5 C 11 Other Specifications Screen 3 color LCD screen Blue Measurement Green Calibration Red Alarm Reading Lock HOLD Low Voltage Warning...

Page 9: ...PH60S E spear pH probe for soft solid samples AI1203 PH60F E flat pH probe for surface test AI1201 PH60 E regular pH probe for general water solutions AI3711 E PH60 DE double junction pH probe for gen...

Page 10: ...E Battery MUST FACE UP WRONG INSTALLATION OF BATTERIES WILL CAUSE DAMAGE TO THE TESTER AND POTENTIAL HAZARDS Loosen the battery cap lock Pull off the battery cap Slide and unlock battery compartment O...

Page 11: ...t s within the 6 month electrode warranty contact us for warranty fulfillment If there is visible damage replace the electrode Instrument defect Contact us for warranty fulfillment Reading keeps jumpi...

Page 12: ...ons beyond our reasonable control To get the fastest warranty fulfillment go to support aperainst com and click New Support Ticket on the upper right corner Type your email in the requester field Warr...

Reviews: