5
XTX Second Stage Regulator Maintenance Manual
An Official Inspection consists of:
1.
A pressurised immersion test of the entire unit to
check for air leakage.
2.
Checking for stable medium pressure that is within
the acceptable range.
3.
Checking for opening effort that is within the
acceptable range.
4.
Checking for smooth operation of the control knob
and venturi switch.
5.
A visual inspection of any filters for debris or dis-
colouration.
6.
A visual inspection of the exhaust valve(s) to see
that they are in good condition and that it is seating
against a clean and undamaged surface.
7.
A visual inspection of the mouthpiece looking for
tears or holes and checking the general condition.
8.
Pulling back hose protectors and checking that the
hoses are secure in the hose crimps.
If a regulator fails steps 1,2,3 or 4 the entire regulator
should be serviced. If a regulator fails 5,6 or 7 it will be up
to the technician’s discretion whether or not a full service
is required. Failure of step 8 requires replacement of the
Hose.
GENERAL GUIDELINES
1.
In order to correctly perform the procedures outlined
in this manual, it is important to follow each step
exactly in the order given. Read over the entire
manual to become familiar with all procedures and
to learn which specialty tools and replacement parts
will be required before commencing disassembly.
Keep the manual open beside you for reference while
performing each procedure. Do not rely on memory.
2.
All service and repair should be carried out in a work
area specifically set up and equipped for the task.
Adequate lighting, cleanliness, and easy access to all
required tools are essential for an efficient repair facil
-
ity.
3.
During disassembly, reusable components should be
segregated and not allowed to intermix with non-
reusable parts or parts from other units. Delicate
parts, including inlet fittings and valve seats which
contain critical sealing surfaces, must be protected
and isolated from other parts to prevent damage
during the cleaning procedure.
4.
Use only genuine Apeks parts provided in the 2nd
stage service kit (AP0219). DO NOT attempt to
substitute an Apeks part with another manufacturer’s,
regardless of any similarity in shape or size.
5.
Do not attempt to reuse mandatory replacement
parts under any circumstances, regardless of the
amount of use the product has received since it was
manufactured or last serviced.
6.
When reassembling, it is important to follow every
torque specification prescribed in this manual,
using a calibrated torque wrench. Most parts are
made of either marine brass or plastic, and can be
permanently damaged by undue stress.
COPYRIGHT NOTICE
This manual is copyrighted, all rights reserved. It may not,
in whole or in part, be copied, photocopied, reproduced,
translated, or reduced to any electronic medium or machine
readable form without prior consent in writing from Apeks
Marine Equipment Ltd. It may not be distributed through the
internet or computer bulletin board systems without prior
consent from Apeks Marine Equipment Ltd.
©2006 Apeks Marine Equipment Ltd.
XTX Second Stage Maintenance Manual
(AP6209F Issue 1)
INTRODUCTION
This manual provides factory prescribed procedures for the
correct maintenance and repair of the Apeks XTX second
stage regulator range. It is not intended to be used as an
instructional manual for untrained personnel. The procedures
outlined within this manual are to be performed only by
personnel who have received factory authorised training
through an Apeks Service & Repair Seminar. If you do not
completely understand all of the procedures outlined in this
manual, contact Apeks to speak directly with a Technical
Advisor before proceeding any further.
WARNINGS, CAUTIONS & NOTES
Pay special attention to information provided in warnings,
cautions, and notes that are accompanied by one of these
symbols:
WARNINGS
indicate a procedure or situation
that may result in serious injury or death if
instructions are not followed correctly.
CAUTIONS
indicate any situation or technique
that will result in potential damage to the
product, or render the product unsafe if
instructions are not followed correctly.
NOTES
are used to emphasise important points,
tips, and reminders.
SCHEDULED SERVICE
It is recommended that the Apeks XTX second stage regulator
should be serviced annually regardless of usage.
However, If at all unsure about the correct functioning of the
Apeks XTX, then it must be officially inspected immediately.
All service and inspection details need to be documented
in the
Regulator Service Record
in the back of the Owner’s
Manual to keep the
Limited Lifetime Warranty
in effect.