![Apec Water RO-PH90 Installation Instructions & Owner'S Manual Download Page 17](http://html1.mh-extra.com/html/apec-water/ro-ph90/ro-ph90_installation-instructions-and-owners-manual_2952288017.webp)
14
Summary of Tubing Connections:
There are 4 connections:
See
Fig. 11 & Fig. 11A.
Point
A
to
X
: Connect RO to COLD water supply —
Red
tubing.
Point
G
to
Y
: Connect product water from 5
th
-stage filter to tank —
Yellow
tubing. This tubing is a 2-way
line, Product water enters and leaves the tank via this line.
Point
P
to
Z
: Connect product water from 6
th
-stage output to RO faucet —
Clear
tubing.
Drain line to
W
: Connect drain water from 4
th
-stage membrane to drain outlet —
Black
tubing.
Fig. 11
Fig.10E
To Disconnect the Tubing:
See
Fig.10B
. Push in and hold down on the collet ring square
against the fitting. With the collet held in this position the tube can
be removed. See
Fig.10E.
Important!
Insert and sleeve Must be installed to prevent water leaking. Metal compression nut must be
fully tightened! (See
Page 8
)