background image

E

LECTRONIC

 

HEAT

 

COST

 

ALLOCATOR

 E-ITN 30.

XX

 EX 

WITH

 

A

REMOTE

 

SENSOR

Description and usage

E-ITN 30.xx EX is a modern electronic device intended for
ratio based allocation of heat cost in buildings with central
heating   system.   Heat   cost   allocator   E-ITN   30.xx   uses  the
two-sensor   measuring   principle   –   integrates   temperature
difference   between   the   sensor   of   the   radiator   surface
temperature and the sensor of the surrounding temperature.
Using  this  principle  the   allocator  ensures   measurement  of
consumption value only when the radiator really emits heat
(i.e. it does not 

measure in the summer).

The   allocator   with   the   remote   sensor   is   equipped   with   a
mechanic and an electronic seal and is delivered in sealed
state   with   the   electronic   seal   activated.   In   case   of
unauthorized removal of the base plate the allocator saves
the date of breach of the electronic seal to its memory and
stops to show measured data on the display. Only the notice
oPEn is displayed and indicates the breach of the electronic
seal but allocator continues measuring and transmitting the
measured   data.   Information   about   the   breach   of   the
electronic   seal   is   available   in   the   data   transmitted   by   the
radio module and via IR interface.

Application

In one-tube horizontal/vertical and two-tube heating systems
with the lowest mean design heating medium temperature 

35   °C   and   highest   mean   design   heating   medium
temperature 

 105 °C.

E-ITN 30.xx EX is not intended for heat cost allocation for
floor heating systems, ceiling radiant heating, flap controlled
radiators,   radiators   with   fan,   systems   with   steam   heating
medium, air heaters and single tube radiators if exceeds the
scope   of   one   user.   It   must   not   be   also   used   for   heating
elements   that   shape   and   design   does   not   allow   reliable
transfer of heat to heat cost allocators.

Each radiator in billing (account) unit with common invoicing
heat meter must be equipped with a heat cost allocator of
the same type. Technical conditions of heating system must
be fulfilled when using heat cost allocators E-ITN 30.xx EX. 

Technical specification

Application

t

min

 

 35 °C

(heating medium)

t

max

 

 105 °C

Measuring principle 

two-sensor meas. principle

Billing period

year

 (E-ITN 30.2 EX, 

E-ITN 30.6 EX)

month

 (E-ITN 30.4 EX, 

E-ITN 30.6 EX)

Dimensions

allocator 100 x 37 x 33 mm 

Operating frequency

868 MHz

 

(E-ITN 30.2 EX, E-ITN 

30.4 EX)

868,95 Mhz 

(E-ITN 30.6 EX)

Transmitting power

< 5 mW or < 1 mW

Conditions

- temperature of the sensor of 

of registration

the radiator temp. 

 23 °C

- difference of mean temp. of 
heating medium and 
surroundings temp. 

 4 °C

Material

ABS + PC / Al – F22 

(E-ITN 30.2 

EX, E-ITN 30.4 EX)
ABS + PC / Al – F (E-ITN 30.6 EX)

IP code

IP 42 

Conformity

 

EN 834 

Dimensional drawings

Installation of E-ITN 30

1. Install the base plate to the radiator according to the 

instructions in Installation and service manual. 

2. Slide the locks in the upper part of the sensor housing 

on the base plate and push the bottom part of the 
housing to the base plate. The allocator must be fixed 
with the latch on both sides of back plate.

3. The base of the allocator is placed on the wall. 

Do not install the allocator if the notice Error or Open is
displayed on LCD.

Activation of E-ITN 30

I the sign  uPr  is displayed  on LCD, the allocator  must be
activated:

1. When LCD is on and notice  uPr is displayed, hold the

button   till   notice    --A

   -  -    appears   that   indicates   sub-

menu activation.

2. Switch   to   item  Act  with   short   button   presses   if

necessary.

3. When notice Act appears, press and hold the button till

notice --A

   -  - is displayed. When you release the button,

first  menu item is displayed.

Reading of measured data

Basic   allocator   status   and   measured   values   can   be
displayed   on   LCD.   The   meaning   of   some   values   may   be
different   if   the   additional   symbol   „SM“   at   the   right   bottom
corner is displayed. These values are mentioned with „SM“
symbol in text , e.g.  385 SM.

The last value shows the termination of the battery lifetime.

1 / 2

To save the battery, after longer period of inactivity (approx.
1   min.),   energy-saving   mode   is   activated     and   display   is
switched   off.  Display   can   be   activated   by   pushing   the
button.

When pushing the button briefly,  notice  -----  on the display
will   appear.  If   the   button   is   not   pushed   in   1 minute,   the
display will switch off.

Displayed data

E-ITN 30.2 EX, E-ITN 30.4 EX

Value for current billing period

245

Value for last billing period

458 SM

Alphanumerical code for last billing period

A.0.i.h.t.

Serial number – first part

-3400

Serial number – second part

0060-

E-ITN 30.6 EX Wireless M-Bus

Consumption for the current billing year

245

Consumption for the past billing year

458 SM

Consumption for the current billing month

2.4.5

Consumption for the past billing month

4.5.8.SM

Serial number – first part

-3400

Serial number – second part

0060-

E-ITN 30.5, E-ITN 30.51 Wireless M-Bus

LCD test

Current date

10.12.

Start of the billing period

u

     1.2.

Value for last billing period

458 SM

Average   surroundings   temperature   for   last
billing period

23.7°C SM

Value for current billing period

245

E-ITN 30.6 Wireless M-Bus

Value for current year billing period

245

Value for last year billing period

458 SM

Value for current month billing period

2.4.5

Value for last month billing period

.4.5.8.SM

Serial number – first part

-3600

Serial number – second part

0060-

* also other items can be displayed based on setting

Transport and storage
Transport

devices can be transported by all usual covered means
of transport

devices must be in original package

originally packed devices must be stored and secured
to avoid mechanical damages during transportation 

devices   can   not   be   transported   together   with
aggressive substances

temperature  during transportation from -10  °C  to +50
°C

relative humidity from 45 % to 75 %

Storage

devices must be originally packed by manufacturer and
individually stored in antistatic bags

storage temperature from +10 °C to +30 °C

relative humidity from 45 % to 75 %

devices must be stored in clean covered areas without
aggressive   substances   and   stored   properly   to   avoid
mechanical damage

Disposal

This   device   is   subject   to   a   waste   management   in
accordance with local legislation.

Possible minor faults and their elimination

Any   E-ITN   30.xx   EX   defect   should   be   repaired   by
manufacturer only.

Warranty terms and conditions

If device is installed and handled according to manufacturer
instructions   mentioned   in   Installation   and   service   manual,
manufacturer   provide   warranty   under   the   valid   legislation
unless agreed differently.

The   warranty   is   void   if   device   was   used   contrary   to
Installation and service manual or damaged:

during transport or storage by customer or reseller

when mounted or dismantled to the customer device

because of improper handling or installation into other
device than agreed in manual

if   the   product   was   exposed   to   different   environment
than agreed in manual

if mechanically or in other way damaged by user

Declaration of conformity, declaration of directive RoHS

You   can   find   declaration   of   conformity   and   declaration   of
directive RoHS on producer´s web page:
www.metra-su.cz

Warranty and post warranty repairs

Warranty   and   post   warranty   repairs   have   to   be   done   by
manufacturer. Pack the defective product and send
back to the manufacturer's address.

2 / 2

Reviews: