Instruction manual
SDQ5PIR
13
Attribute
Description
Commands
Value
Factory
default
SDQLVL
Volume level
GET, SET, INC,
DEC
OFF (-64)
-63 to 0
0
MAXLVL
Maximum allowed
level
GET, SET
BACK, OFF (-64)
-63 to 0
BACK
BALANCE
Left - right balance
GET, SET
-31 to 31
0
SELECT
Source selection
GET, SET
A, B, AB, or WI
AB
EQBASS
Equalizer bass
GET, SET
-14 to 14
(stepsize = 2)
0
EQTREB
Equalizer treble
GET, SET
-14 to 14
(stepsize = 2)
0
STANDBY
Standby state
GET, SET
ON or OFF
OFF
IPGAIN
Input gain
GET, SET
0 to 3
A,B,WI at 0
AB at 2
ECHO
RS232 echo
GET, SET
ON or OFF
OFF
LF
RS232 line feed
GET, SET
ON or OFF
OFF
BS
RS232 backspace
GET, SET
ON or OFF
ON
VALFB
RS232 value feedback
GET, SET
ON or OFF
ON
BACKCT
Back panel control
GET, SET
ON or OFF
ON
WALLCT
Wall panel control
GET, SET
ON or OFF
ON
IRRMCT
Infrared remote control
GET, SET
ON or OFF
ON
AUTOPW
Auto power off
GET, SET
0 to 30
0 (OFF)
AUPTRG
Auto power trigger
level
GET, SET
0 to 9
1
INFO
settings information
GET
NA
NA
HWVRSN
Hardware version
GET
NA
NA
SWVRSN
Software version
GET
NA
NA
RESTORE
Restore factory
defaults
SET
ON
NA