background image

SDQ5PIR

Instruction manual

Summary of Contents for SDQ5Pir

Page 1: ...SDQ5PIR Instruction manual ...

Page 2: ......

Page 3: ...Instruction manual SDQ5PIR 1 SDQ5PIR Manual ...

Page 4: ...s recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplifier be protected by hearing protection while installing or operating this unit Read all documentation before operating your equipment Keep all documentation for future reference Save the carton and packing material even if the equipment has arrived in good condition Should you eve...

Page 5: ...evices Do not operate equipment on a surface or in an environment which may distort the normal flow of air around the unit If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of dust Do not remove the cover Removing the cover will expose you to potentially dangerous volt ages Do not drive the inputs with a signal level higher than that required...

Page 6: ...justable maximum level multiple inputs unbalanced on mini jack and balanced on euroblock additional input via optional wall control unit All inputs can be gain adjusted used individually or mixed together except optional wall control panel local input source this input cannot be mixed with the A or B or A B inputs The automatic power on function will power up the speaker automatically when a suffi...

Page 7: ...included RS232 wall panels optional RS232 control for increased integration in automated audio systems using standard 9 pin serial cable RJ45 remote wall panel connector not compatible with computer networks or other types of remote control cabling These speakers have been carefully packed at the factory Open the carton box and remove the speakers from the packing Do not use sharp objects Place th...

Page 8: ...ontrol to neutral position 3 Bass control add or decrease the low frequencies Decreasing bass can improve the intelligibility of spoken messages especially in reverberant rooms push the or button once to increase or decrease the bass tone control in steps of 2 dB Push both and buttons simultaneously to reset the bass tone control to neutral position 4 On Off turn the unit on or off with this butto...

Page 9: ...ll sound through both speakers 11 Mains socket connect the supplied mains cord here This socket contains a 1 A slow acting fuse Use a screw driver to flip out the fuse compartment to access a broken fuse When this fuse blows frequently you should return the SDQ to your dealer for service 12 Heat sink the heat sink will warm up during operation This is normal 13 Wall panel connector standard RJ45 c...

Page 10: ... SET STANDBY OFF CR If you want to send any other command while the unit is in standby mode it will wake up from standby and reply STANDBY OFF CR After that resend the command and it will be executed An instruction has at least a command and an attribute In many cases there are extra values needed like a source name character or a value From here we assume that you are familiar with RS232 communic...

Page 11: ...g if the MAXLVL is 10 and you enter the command SET SDQLVL 20 CR the SDQ5PIR will set the level relative to the MAXLVL which was 10 Please note that the absolute maximum number of volume steps is limited to 64 steps 1 volume step corresponds to 1 25 dB The MAXLVL parameter is therefore considered as the master volume If you want to mute the speaker you can set the MAXLVL parameter to OFF BALANCE s...

Page 12: ... will be Command Executed CR A command to set the input gain of source A to 1 looks like this SET IPGAIN A 1 CR AUPTRG auto power trigger level Range from 0 to 30 Higher values will increase the trigger level RS232 settings All RS232 settings are binary values they can be ON or OFF If ECHO is on all received characters are echoed back This can be handy when programs like hyperterminal are used LF ...

Page 13: ...ues are on or off When value feedback in on the SDQ5PIR will reply its setting after a value has been changed such as SDQLVL Control settings BACKCT set the controls at the back of the unit on or off NOTE when set to off you can NOT operate the unit from the back panel controls WALLCT set the control of the optional wall control panel on or off IRRMCT set the control by infrared remote on or off A...

Page 14: ... will be restored The SDQ5PIR can be switched to Standby mode with the IR remote control or with the SET STANDBY ON CR instruction Leaving Standby mode can also be done with IR remote controller or the SET STANDBY OFF CR instruction If an RS232 instruction is sent when the amplifier is in Standby mode or during power on and the amplifier is not ready it will answer STANDBY ON CR Please wait until ...

Page 15: ... SET ON or OFF OFF IPGAIN Input gain GET SET 0 to 3 A B WI at 0 AB at 2 ECHO RS232 echo GET SET ON or OFF OFF LF RS232 line feed GET SET ON or OFF OFF BS RS232 backspace GET SET ON or OFF ON VALFB RS232 value feedback GET SET ON or OFF ON BACKCT Back panel control GET SET ON or OFF ON WALLCT Wall panel control GET SET ON or OFF ON IRRMCT Infrared remote control GET SET ON or OFF ON AUTOPW Auto pow...

Page 16: ...efore first use carefully remove the transparent battery saver When the battery is empty replace with the same type only Slide out the battery holder from the remote control unit remove the empty battery and put a fresh one in place The battery holder has a mark on it Make sure you insert the battery and holder in the right way IR eye receiver ...

Page 17: ...isassemble or incinerate this type of battery Keep all batteries away from children Dispose of used batteries promptly and as regulated by applicable laws function IR command function IR command Power ON 12 Level Down 06 STANDBY 1A MUTE 09 Input A 01 Bass UP 0C Input B 04 Bass DOWN 00 Input A B 07 Treble UP 0D Input WALL 0A Treble Down 0F Level UP 03 SDQ5PIR device code is 807F Infrared commands h...

Page 18: ...put sensitivity balanced input B 175 mVrms 15 dBV tone control bass 14 dB 100 Hz in 2 dB steps tone control treble 14 dB 10 kHz in 2 dB steps balance control 31 steps 1 25 dB per step input gain adjustment 0 to 3 3 75 dB per step dynamic output power 2 x 30 watts max SPL 1 m 101 dB SPL 1 W 1 m 86 dB frequency range 45 20 kHz THD 0 07 S N ratio 90 dB power supply 230 VAC 80 W max fuse rating T 1 AL...

Page 19: ...5 kg slave shipping weight 6 2 kg 1 set shipping dimensions mm 270 x 210 x 440 accessories supplied power cord bracket manual infrared remote control unit slave speaker connection wire remote control unit battery type lithium CR2025 3v applicable in 100 V yes applicable low impendance yes active yes operating temperature 10 to 40 C relative humidity 10 to 90 non condensing ...

Page 20: ...part Audio NV Industriepark Brechtsebaan 8 bus 1 2900 Schoten Belgium Company names product names and trademarks are property of their respective owners Apart Audio specifications are subject to change without notice ...