PM1122-INT DIGITAL INTERFACE REMOTE
WWW.APART-AUDIO.COM / [email protected]
Easywave
An
optional
Easywave
receiver
module
can
be
mounted
inside
the
PM1122
‐
INT.
To
install
this
receiver,
please
carefully
remove
the
top
cover
and
slide
the
module
in
place
like
shown
on
the
picture
below.
Once
this
module
is
installed,
an
eight
button
RF
switch
can
be
assigned
to
a
zone
of
the
PM1122.
4
buttons
named
A
to
D
are
used
for
selecting
the
source
or
to
recall
a
preset.
By
default,
these
buttons
are
configured
to
select
source
A
to
D.
Next
to
that
are
an
up
and
down
button
controlling
the
music
level
and
finally
the
same
2
buttons
controlling
the
microphone
level.
Assigning
an
RF
switch
is
as
simple
as
pushing
the
“Learn”
button
from
the
corresponding
zone
(x)
and
then
push
any
buttons
of
the
RF
switch
within
5
seconds.
In
case
the
PM1122
‐
INT
is
in
a
less
accessible
place,
this
can
also
be
done
by
an
RS232
instruction.
“LRN
RFKEY
ZONEx<CR>”
has
the
same
effect
as
pushing
the
“Learn”
button
from
zone
x.
Clearing
of
the
memory
or
un
‐
assigning
the
RF
switches
also
can
be
done
in
2
ways:
pushing
the
“Clear”
button
on
the
PM1122
‐
INT
for
at
least
2
seconds
or
by
the
instruction
“CLR
RFKEY
ALL<CR>”.
Two
extra
features
can
be
configured
by
RS
‐
232:
•
“Mute”
‐
buttons:
the
music
level
or
mic
mix
level
will
be
put
at
minimum
if
the
level
down
button
is
double
clicked.
To
enable
this
feature,
the
following
RS
‐
232
command
should
be
executed:
“SET
DBLCLICK
ON<CR>”.
Corresponding,
the
feature
can
be
disabled
by
the
9