background image

1.

Install the ionizing air blower and the matching power adapter firmly in the best discharge position.

2.

Insert the power network cable into the adapter and the ionizing air blower RJ45 network port, and insert the three-phase power cable of the

 

adapter into the row socket.

3. The overhead air blower can also be directly powered by 220VAC

. The actual power supply is 220VAC when both 220VAC and 24VDC are 

connected to the fan.

4.

Touch the power switch on the front panel of ionizing air blower. It will automatically brush the needle after starting and the fan works normally

 

when the indicator light is green.

Installation steps

Technical tips

Wall

Packing accessories

AP2930003

1

8YXG25110

1

8WXI00004

1

AP2253011 

1

Products Use

Installation steps/technical tips/Packing accessories

1. Place the  ionizing air blower in the work area where static electricity is to be eliminated and the installation angle is perpendicular to the surface

of the charged body.

2. Ionizing air blower should be at least 300mm away from the metal conductor and metal grounding body. The ionizing air blower must be

reliably connected to the ground wire.

3. Two ionizing air blowers should be installed side by side with an interval of more than 400mm and more than 200mm away from obstacles such 

as walls.

4. The air inlet is at least 150mm away from the wall.

Part name

Picture

Part No.

Specification

Q'TY

Power adapter

GRT-240200

DC24V 2A

Dual-port output

size

123*61*40.5mm

L*W*H

National standard 

power cord

Standard 1.8m

Optional 3m/5m

Power cable

Standard 2.5m

Optional  5m/10m

Remote control

IR remote control

84×38mm

400

Wall

Wall

Wall

Wall

Wall

Wall

Summary of Contents for AP-DJ2814

Page 1: ...Intelligent Control Network LED Display Ionizing Air Blower AP DJ2814 Shanghai Anping Static Technology Co Ltd AP TR AP T New Product Intelligent Control Network LED Display Ionizing Air Blower...

Page 2: ...ms caused by static electricity Suitable for electronics optoelectronics semiconductor and other industries Static removal Prevent blockage of feeder Prevent static electricity Prevent material splash...

Page 3: ...ring Monitoring the working status of ionizing air blower online RS485 communication AP DY6703 AP KT3701 AP DY6704 USB wire link USB wire link IMS monitoring software IMS monitoring software IMS monit...

Page 4: ...Button Function instructions Unlock Run Pause Clean Adjust clean time Adjust air volume Adjust ion balance Confirm Reset Unlock before adjusting operating parameters 30s delay if any key is pressed ex...

Page 5: ...of the object Increase Tp so that the positive voltage acting capacity becomes greater and the acting time becomes longer More positive ions and less negative ions output to neutralize the excess nega...

Page 6: ...5 X mm 150mm 300mm 450mm 525 600mm 250 Discharge time distribution diagram of AP DJ2814 Ion balance distribution diagram of AP DJ2814 Test Length mm Test Length mm Discharge Time s Ion Balance V Test...

Page 7: ...ly brushed every 4 hours for manual cleaning and maintenance free Fault alarm Display screen show fault alarm and LED red light alarm when the fan ion balance and high voltage breakdown No 5 Network M...

Page 8: ...cing function The self balancing range is 10V and the balance voltage can be displayed in real time Intelligent remote control The negative high voltage amplitude is adjustable which can be used to ad...

Page 9: ...t 28 Temperature of the current operating environment 62 RH Humidity of the current operating environment Cleaning Cleaning indication Fan Fault Fan fault alarm HV Warning High voltage fault alarm Gre...

Page 10: ...t 4 85KG 1Year CE Specification Installation accessories 1 pair of L shaped aluminum powder spraying mounting brackets 1 pair of bakelite screw handles M5 8 Unit mm Dimensions 49 13 30 65 150 165 2 R6...

Page 11: ...Products Use Installation steps technical tips Packing accessories 1 Place the ionizing air blower in the work area where static electricity is to be eliminated and the installation angle is perpendic...

Page 12: ...Faults The indicator on the fan panel is off The electrostatic removal performance decreased obviously The electrostatic removal performance decreased High voltage ion balance alarm Panel indicator l...

Page 13: ...repairing 2 Do not press or rotate the control buttons on the fan panel too hard otherwise the device will be permanently damaged 3 If the working indicator light on the front panel of the fan is off...

Page 14: ...g analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Addr...

Reviews: