1.
The ionizing air blower should be cleaned and maintained in time according to the use environment and the required electrostatic
protection requirements in order to ensure the good performance of the product. That is, gently remove the carbon deposits on the
discharge electrode and metal
net
cover with electrostatic brush, dust-free cloth dipped in anhydrous alcohol. Note:
A
、
Operation must be done 10 minutes after power cut off.
B
、
It must be cleaned when dust or white stuff appear on the tip of the needle during use.
C
、
The ionizing air blower must be powered on after alcohol is completely volatilized after cleaning. No other organic solvent can be
used to clean the ionizing air blower.
D
、
The alloy electrode is a consumable product which is not included in the scope of warranty and will be charged for replacement
when repairing.
2. Do not press or rotate the control buttons on the fan panel too hard; otherwise, the device will be permanently damaged.
3. If the working indicator light on the front panel of the fan is off or red, it should be stopped and repaired by professional maintenance
personnel. It can be used only after the electrical performance index is normal.
Safety warning
Trouble shooting
After-sales service
Maintenance
NO
Problems
Reasons
Solutions
1
The indicator on the fan
panel is off
Poor contact of the power cable
Check whether the power cable is in good condition and
securely connected
Power supply mismatch
Confirm the power supply specification
(
INPUT
:
100—
240VAC 50/60Hz
;
OUTPUT
:
15VDC 2000mA
)
2
The electrostatic removal
performance is obviously
reduced
Discharge needle is polluted and damaged
Clean or replace the discharge needle
Bearing set of ionizing air blower is improper
Confirm the best bearing set
3
The electrostatic removal
performance is reduced
There are conductors or other ionizing air blowers around Remove (moving) conductors or other ionizing air blowers
4
Unable to discharge
High voltage module is damaged
Return to factory for maintenance
Main-board chip is damaged
Return to factory for maintenance
5
The product is smoky or burnt
The main control board components are burnt out
Return to factory for maintenance
1.
AP- DC2451-001
self-cleaning desktop ionizing air blower
has undergone rigorous testing and aging treatment before ex-work.
Its
performance has completely reached the relevant indicators marked in the usage instruction.
2. AP&T makes a commitment to the customer that any defective parts inspected by AP&T will be repaired or replaced free of charge
within one year from the date of purchase. However, this commitment does not apply to:
The device is incorrectly used or installed
;
Damage caused by negligence or accident during use
;
Modified, disassembled or repaired by other service departments not authorized by
Anping Company.
3. AP&T shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above.
1. Read the operating instruction carefully before installing and using the device.
2. Do not insert foreign objects into the inlet or outlet of the ionizing air blower.
3. Do not use the device when the humidity is higher than 70%.
4. Do not use the device in inflammable and explosive environment.
5. It is strictly forbidden to disassemble products without authorization. Internal maintenance and repair must be carried out by
professional personnel.
6.
The product is strictly prohibited to touch liquid during use
, otherwise there will be abnormal, resulting in electric shock or fire.
7. Power must be turned off during inspecting or replacing the product, otherwise it may cause electric shock or fire.
8. The product is specially designed for removing static electricity and is strictly prohibited for other purposes. Any abnormal use
may cause machine failure, electric shock, fire and other hidden dangers.
9. It is strictly forbidden to touch the electrode needles when power is on, otherwise it is easy to cause fault and electric shock
accident.
10.Discharge needle is a sharp metal object, please use it with care.
11.Please check the specifications of the power supply before powering on the product. Any power supply that does not meet the
specifications may cause damage or even failure to the product.
12.Check the power cord regularly. If it is damaged, replace it immediately; otherwise, leakage and abnormal operation may occur.
Summary of Contents for AP-DC2451-001
Page 3: ...Speciality Creates Value...