background image

1.

The ionizing air blower should be cleaned and maintained in time according to the use environment and the required electrostatic

 

protection requirements in order to ensure the good performance of the product. That is, gently remove the carbon deposits on the

 

discharge electrode and metal 

net

 cover with electrostatic brush, dust-free cloth dipped in anhydrous alcohol. Note:

A

Operation must be done 10 minutes after power cut off.

B

It must be cleaned when dust or white stuff appear on the tip of the needle during use.

C

The ionizing air blower must be powered on after alcohol is completely volatilized after cleaning. No other organic solvent can be

 

used to clean the ionizing air blower.

D

The alloy electrode is a consumable product which is not included in the scope of warranty and will be charged for replacement

 

when repairing.

2. Do not press or rotate the control buttons on the fan panel too hard; otherwise, the device will be permanently damaged.

3. If the working indicator light on the front panel of the fan is off or red, it should be stopped and repaired by professional maintenance 

personnel. It can be used only after the electrical performance index is normal. 

Safety warning

Trouble shooting

After-sales service

Maintenance

NO

Problems

Reasons

Solutions

1

The indicator on the fan 

panel is off

Poor contact of the power cable

Check whether the power cable is in good condition and  

securely connected

Power supply mismatch

Confirm the power supply specification

INPUT

100—

240VAC 50/60Hz

OUTPUT

15VDC 2000mA

2

The electrostatic removal 

performance is obviously 

reduced

Discharge needle is polluted and damaged

Clean or replace the discharge needle

Bearing set of ionizing air blower is improper

Confirm the best bearing set

3

The electrostatic removal 

performance is reduced

There are conductors or other ionizing air blowers around  Remove (moving) conductors or other ionizing air blowers

4

Unable to discharge

High voltage module is damaged

Return to factory for maintenance

Main-board chip is damaged

Return to factory for maintenance

5

The product is smoky or burnt

The main control board components are burnt out

Return to factory for maintenance

1.

AP- DC2451-001 

self-cleaning desktop ionizing air blower

 has undergone rigorous testing and aging treatment before ex-work.

 

Its 

performance has completely reached the relevant indicators marked in the usage instruction.

2. AP&T makes a commitment to the customer that any defective parts inspected by AP&T will be repaired or replaced free of charge

 

within one year from the date of purchase. However, this commitment does not apply to:

 

The device is incorrectly used or installed

;

Damage caused by negligence or accident during use

Modified, disassembled or repaired by other service departments not authorized by 

Anping Company.

3. AP&T shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above.

1. Read the operating instruction carefully before installing and using the device.

2. Do not insert foreign objects into the inlet or outlet of the ionizing air blower.

3. Do not use the device when the humidity is higher than 70%.

4. Do not use the device in inflammable and explosive environment.

5. It is strictly forbidden to disassemble products without authorization. Internal maintenance and repair must be carried out by 

professional personnel.

6.

The product is strictly prohibited to touch liquid during use

, otherwise there will be abnormal, resulting in electric shock or fire. 

7. Power must be turned off during inspecting or replacing the product, otherwise it may cause electric shock or fire.

8. The product is specially designed for removing static electricity and is strictly prohibited for other purposes. Any abnormal use 

may cause machine failure, electric shock, fire and other hidden dangers.

9. It is strictly forbidden to touch the electrode needles when power is on, otherwise it is easy to cause fault and electric shock 

accident.

10.Discharge needle is a sharp metal object, please use it with care.

11.Please check the specifications of the power supply before powering on the product. Any power supply that does not meet the 

specifications may cause damage or even failure to the product.

12.Check the power cord regularly. If it is damaged, replace it immediately; otherwise, leakage and abnormal operation may occur.

Summary of Contents for AP-DC2451-001

Page 1: ...Self cleaning Desktop Ionizing Air Blower AP DC2451 001 Self cleaning Desktop Ionizing Air Blower AP TR Shanghai Anping Static Technology Co Ltd AP T...

Page 2: ...ms caused by static electricity Suitable for electronics optoelectronics semiconductor and other industries Static removal Prevent blockage of feeder Prevent static electricity Prevent material splash...

Page 3: ...Speciality Creates Value...

Page 4: ...and negative air ions which are blown by the axial fan to the surface of objects with electrostatic to be eliminated It is suitable for electronics optoelectronic semiconductor plastic film printing a...

Page 5: ...hours for manual cleaning and maintenance free No 3 Dedicated external power adapter INPUT 100 240V 50 60Hz OUTPUT DC15V 1000mA CE certification CE certified which is a high security and high reliabil...

Page 6: ...ew handle Power input socket Metal net cover Mounting brackets 6 5 4 3 2 1 140 152 180 117 60 201 5 185 140 55 7 U shaped bracket Power switch Working status indicator Power input socket Front Back Ba...

Page 7: ...on indicates working normally Air volume 89 1CFM Noise 43db 1m away from the air outlet Ozone thickness 0 05ppm 150mm away from the air outlet Working temperature 0 50 Working humidity 30 70 RH Dimens...

Page 8: ...electricity is to be eliminated And the installation angle should be perpendicular to the surface of the charged body and about 300 to 750 mm away from the static electricity object 2 Ionizing air blo...

Page 9: ...smoky or burnt The main control board components are burnt out Return to factory for maintenance 1 AP DC2451 001 self cleaning desktop ionizing air blower has undergone rigorous testing and aging tre...

Page 10: ...g analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Addr...

Reviews: