Test standard
:
ANSI/ESD.STM3.1
,
SJ/T 11446—2013
Test instrument: Trek 157 static tester
Test voltage
:
±1000V → ±100V attenuation
Test environment
:
humidity 50±5%
;
temperature 23±3
℃
The test data as follows (test distance: 300mm in front, maximum air volume):
The ionizing air blower adopts the synchronous
emission technology of positive and negative ions,
which use two sets of independent emitter electrodes to
generate a direct current corona discharge to produce a
large number of positive and negative air ions, which
are blown by the axial fan to the surface of objects with
electrostatic to be eliminated. It is suitable for
electronics, optoelectronic, semiconductor, plastic,
film, printing and other industries
.
5.5
s
7.1
s
+1
V
+
-
3.0
s
4.6
s
-2
V
+
-
1.7
s
2.4
s
-2
V
+
-
1.1
s
1.4
s
-2
V
+
-
20.8
s
37.0
s
-2
V
+
-
300
mm
6.5
s
7.7
s
-1
V
+
-
600
mm
6.8
s
8.2
s
-1
V
+
-
900
mm
+1
V
1200
mm
-2
V
5.9
s
6.9
s
-2
V
5.7
s
7.3
s
-1
V
+
-
7.8
s
10.7
s
-1
V
+
-
10.9
s
11.2
s
+
-
16.8
s
23.6
s
+
-
+
-
300
mm
300
mm
0
mm
DC
DC
T
Steady-state DC
+HV
(
Positive high voltage
)
-HV
(
Negative high voltage
)
Discharge effect
Working way
Keep a clean production environment and stay
away from static electricity
High Efficiency Static Removal
Positive high voltage
Negative high voltage
Summary of Contents for AP-DC2451-001
Page 3: ...Speciality Creates Value...