E n g l i s h
| 23
Press
to save changes.
The technician can configure the oven with the “Advanced” button.
Press “My account” to display account and password used to access the CLOUD service.
4.3.
Warnings and alarms
In this folder you can find all the history of the alarms that triggered, useful for any maintenance work. You
can save the alarms list via USB by pressing
or delete every alarm by pressing
.
4.3.1.
List of alarms
ALARM
SOLUTIONS
Serial communication error
Check the cables connection between the display board and the
power board
FW incompatibility
Contact customer service
Chamber probe error
1-
Check that the chamber probe is properly connected
2-
Replace chamber probe
Core probe error
1-
Check that the core probe is properly connected
2-
Replace core probe
Optional core probe error
1-
Check that the core probe is properly connected
2-
Check that the connector is properly connected to the
power board
3-
Replace core probe
Probe board error
Contact customer service
Maximum
temperature
in
the
chamber
Contact customer service - The maximum temperature has
exceeded the set point value abnormally.
Fans thermal protection
Check proper operation of the fan motors
Safety thermostat protection
Contact customer service
High energy consumption
Contact customer service - Check the appliance's input voltage
Board high temperature
1-
Make sure that the room is well ventilated
2-
Verify that the cooling motor is properly working
4.4.
Date time and language
In this folder you can change everything about time, data, time zone, device language and keyboard layout.
4.4.1.
Change keyboard and language
To change the language:
Click on the entry “language”.
Choose the desired language.
The keyboard layout changes automatically according to the chosen language.
Press