background image

12  

 

 

OPERATING GUIDELINES 

G. TEMPERATURE SCALE 
 

The displayed temperature can be toggled between the centigrade 

scale or the Fahrenheit scale. 
To switch between the two scales follow these procedures: 
1.  With the unit turned On, Press and hold the SET button to enter the 

system configuration mode.  

2.  Repeatedly press the “SET” button until “ C°” or “ F°”  is displayed. 

This   denotes   that   we   are   now   configuring   temperature   scale 
settings. 

3.  “C°”  indicates  that  the  current  system  scale  is  Centigrade.  “F°”  

denotes   the  selected  temperature  scale  is   the  Fahrenheit  scale. 
Press  the  increase  or  decrease  button  to  select  between  the  two 
temperature scales. 

4.  To  save  the  temperature  scale  settings,  repeatedly  press  the  SET 

button until the display shows the word “SAVE”. Press the increase 
button to save and exit from the system configuration mode. 

◆ 

The   temperature   display   would   change   according   to   the   scale 
selected. A suffix “F” /“###F” indicates the  Fahrenheit scale, while 
“C” /“###C” indicated the Centigrade scale. 

 
H. POWER LED  
 

For tools with LED  capabilities only.   

To switch between the On and Off: 
1.  With the unit turned On, Press and hold the SET button to enter the 

system configuration mode.  

2.  Repeatedly press the “SET” button until “ POFF”  is displayed. This 

denotes that we are now configuring Power LED settings. Press up 
and down button to select between ON and OFF. 

3.  “OFF” indicates that the LED is turned OFF. “ON”  indicates LED is 

turned on.  

4.  To  save  the  settings,  repeatedly  press  the  SET  button  until  the 

display  shows  the  word  “SAVE”.  Press  the  increase  button  to  save 
and exit from the system configuration mode. 

Note:  During  system  configuration  mode  if  it  is  decided  that 
the recently changed setting should not be saved into system 
memory,  repeatedly  press  the  set  button  until  the  display 
shows the word “CncL” (cancel). Press the decrease button to 
exit   system   configuration   mode   without   saving   the   most 
recent changes made. 

5  

 

 

           CAUTION: 

Improper usage can cause serious injury to personnel and/or   

 

 

damage to equipment and work area. For your own safety, please observe  

 

 

the following precautions.

 

SAFETY PRECAUTIONS 

● 

Check   each   component   after   opening   the   package   to   make   sure 

everything  is  in  good  condition.  If  there  are  any  suspected  damage,  do 

not use the item and report the issue to your vendor. 

● 

Turn  OFF  the  main  power  switch  and  unplug  the  device  from  power 

source when moving the device. 

● 

Do not strike or subject the main unit (and all its components) to physical 

shock.  Use carefully to avoid damage to any part. 

● 

Handle with care. 

      - Never drop or sharply jolt the unit. 

      - Contains delicate parts that may break if the unit is dropped. 

● 

Make sure the equipment is always grounded. Always connect power to a 

grounded receptacle. 

● 

Temperature may reach as high as 480°C when switched ON. 

       - Do not use the device near flammable gases, paper and other flammable 

materials. 

      - Do not touch heated parts, which can cause severe burns. 

      - Do not touch metallic parts near the tip. 

● 

Disconnect the plug from the power source if the unit will not be used for 

a long period. 

 

  - Turn off power during breaks, if possible. 

● 

Use only genuine replacement parts. 

 

  - Turn off power and let the unit cool down before replacing any part. 

● 

The unit may produce a small amount of smoke and unusual odor during 

initial usage. This is normal and should not yield any negative result when 

reworking. 

● 

Soldering process produces smoke — use on well ventilated places. 

● 

Do not alter the unit, specifically the internal circuitry, in any manner. 

 

Summary of Contents for INT9378

Page 1: ...n City Guangdong Province P R China http www aoyue com Thank you for purchasing the Aoyue Int9378 Soldering Station Please read the manual before using the unit Keep manual in accessible place for fut...

Page 2: ...afety Precautions section explains the hazards of using any type of soldering or reworking device Please read carefully and observe the guidelines in order to maximize usage and minimize the risk of i...

Page 3: ...d Display shows low tem perature levels then switches to Err2 SOLUTION The heating element is damaged Replace heating element Or check the wirings of the solder iron pen PROBLEM 3 SOLDER IRON TIP IS O...

Page 4: ...when soldering Standard temperature settings are 350 to 400 degrees Celsius Cleaning Always clean the soldering tip before use to remove any residual solder or flux adhering to it Use a clean and mois...

Page 5: ...is decided that the recently changed setting should not be saved into system memory repeatedly press the set button until the display shows the word CncL cancel Press the decrease button to exit syste...

Page 6: ...on to save and exit from the system configuration mode F SYSTEM LOCK The System lock feature disables adjustment to both temperature and system configuration The display will show SAFE when system loc...

Page 7: ...control buttons Sleep timer is configurable via the following method 1 With the unit turned On Press and hold the SET button to enter the system configuration mode 2 Repeatedly press the SET button un...

Page 8: ...tem configuration mode Wait for the display to change to 01 meaning current tool 01 9 4 Press the set button again to scroll to the Digital offset function The display shows a number with an A as its...

Reviews: