Introduction

 

 
Thank you for purchasing this quality product.

 To minimize the risk of injury we urge that our clients 

take some basic safety precautions when using this device. Please read the operation instruc-
tions carefully and make sure you have understood its content.

 

Keep these operation instructions safe. 

 
 
Product description and information

 

 

 

The IR preheating station INT853A is a reworking device using infrared (IR) heating technology 
with a multifunctional circuit board holder. It is designed for reworking double-sided print circuit 
boards (PCBs) with various technologies to be soldered with or without lead. 

 

The system has a powerful IR heating element, a digital display with turning knob control and 
simple switching between Celsius and Fahrenheit scale. Its unique and innovative design with 
CPU control offers precision, safety, and user-friendliness in order to comply with all reworking 
needs. 

 
 

Functions

 

 

 

Microprocessor controlled equipment 

 

Digital display of actual temperature and set temperature, knob control for precision and user-
friendliness 

 

Temperature scale switchable between Celsius and Fahrenheit 

 

Multifunctional integrated board holder 

 

Board holder with multiple turn handle and angle handle 

 

Suitable for soldering with and without lead 

 

Widespread for reworking BGAs, micro BGAs, QFPs, PLCCs, SOICs, small SMDs and other 
circuit board components. 

 

Preheating temperature easy to configure with digital display 

 

Equipment protected from electrostatic discharges 

 

Compatible with hot air or IR top heating systems 

 
 

Technical specifications

 

 

Intake voltage 

(V) 

220 

Intake frequency

 (

50 

Power consumption

 (W) 

500 

Temperature range 

(

80

–450 

Size 

(

190 × 155 × 265 

Weight

 (

2.68 

Features

 

3-digit display 
protected from electrostatic discharges 

Heating element

 

Quartz IR 

 

 

Summary of Contents for INT853A

Page 1: ...operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...vice wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschwei...

Page 3: ...ching between Celsius and Fahrenheit scale Its unique and innovative design with CPU control offers precision safety and user friendliness in order to comply with all reworking needs Functions Microprocessor controlled equipment Digital display of actual temperature and set temperature knob control for precision and user friendliness Temperature scale switchable between Celsius and Fahrenheit Mult...

Page 4: ...ug when moving the device Avoid exposing parts of the device to excessive mechanical stress knocks blows etc Caution Perform a visual inspection of the device before each use Do not use the device if safety de vices are damaged or worn Never override safety devices Only use the device for the purpose specified in these operating instructions You are responsible for the safety in the work area If t...

Page 5: ...ble substances such as gases paper or others Avoid touching hot parts of the station otherwise you could be seriously burned Do not touch the metallic parts near the soldering tips Temperature protection The device is equipped with an automatic temperature protection which switches off the device if one of the temperatures is too high The device switches on again when the status has returned to no...

Page 6: ...ik GmbH Item 90853A Page 6 http www WilTec de http www aoyue eu 09 2021 1 http www teichtip de Explanation of the control panel Name Name 1 Temperature display 3 Temperature regulator 2 Heating display 4 Temperature scale switch ...

Page 7: ...re is shown on the display and after a moment the actual temper ature of the heating element To set the desired temperature turn the temperature control 3 The set temperature is shown on the display As soon as the temperature is set the display switches to showing the actual temperature You can switch between the Fahrenheit and Celsius display by pressing the temperature scale switch 4 The heating...

Page 8: ... European countries with a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of yo...

Reviews: