8
88
8
PROBLEM 1: THE UNIT HAS NO POWER
1. Check if the unit is switched ON.
2. Check the fuse. Replace with the same type if fuse is blown.
3. Check the power cord.
4. Verify that the unit is properly connected to the power source.
PROBLEM 2: TEMPERATURE DISPLAY IS ALWAYS ABOVE 400
o
C
Description:
Constant display of above 400
o
C temperature
from the panel
then displays “Err” on the panel after a few minutes.
SOLUTION:
The thermal sensor may be broken and needs to be replaced.
PROBLEM 3: TEMPERATURE DISPLAY IS ALWAYS BELOW 60
o
C
Description:
Constant display of below 60
o
C temperature
from the panel
then displays “Err” on the panel after a few minutes.
SOLUTION:
Turn OFF unit and then ON again. If Display still shows “Err” then the
Heating element may be broken and needs to be replaced.
PROBLEM
4:
DISPLAY
PANEL
SHOWS
UNRECOGNIZABLE
CHARACTERS
SOLUTION :
Switch unit OFF, wait a few seconds and ON again. If problem
persists contact vendor
OTHER PROBLEMS NOT MENTIONED:
Contact the vendor.
OPERATING GUIDELINES
Automated Hot Bar
Soldering System
INSTRUCTION MANUAL
Thank you for purchasing the AOYUE 8011
Automated Hot Bar Soldering System.
Please read this manual before operating the equipment.
Keep manual in accessible place for future reference.
8011