background image

                                                  

                                                  

                                                  

                                                  2

22

  

  

  

 

 

Main Station  

Power input:  

220V 

Station Dimensions:  

400(w)x580(h)x580(d)mm 

Power consumption:  

500W peak 

Temperature range:  

100°C - 350°C 

 The  8011  Automated  Hot  Bar  Soldering  System  is  equipped 

with a three way micro adjust system two Powerful magnified 

camera  and  LCD  screen  for  precise  movement  adjustment. 

Its  CPU  controlled  timer  and  temperature  controls  provide 

precise timing and temperature stability. Finally its automated 

pneumatic system provides accurate and easy repeatability . 

SPECIFICATIONS 

Specifications are subject to change without prior notice 

PRODUCT DESCRIPTION 

TABLE OF CONTENTS 

Product Description  ———————————–—  2 

Specifications  ————————————–———  2 

Safety Precautions  ———————–—————— 3 

Initial Setup  ————————–————————  3 

Control Panel Guide  ———–-—————————  4 

Operating Guidelines  ————————--—-  5 — 7 

Basic Troubleshooting Guide  ————–—–——— 

8  

7

77

  

  

  

 

 

7.  Upon finishing one complete automated cycle the previously entered 

temperature and timer settings will be saved to the CPU memory. 

 

Note: 

The Emergency stop button can be used to stop the hot bar tool from 

automatically descending. (see “Emergency stop button” for details) 

 

5. 

MANUAL CONTROL  

1.  Automatic  or  Manual  Control  can  be  selected  by  pressing  the 

SELECT button. (“10”  from control panel guide).  

2.  When  the  RED  Lamp  is  lighted  it  means  the  system  is  currently  in 

Manual control mode. 

3.  If  the  Green  Lamp  is  lighted  the  system  is  in  automatic  control 

mode, push the SELECT button to switch to manual control mode. 

4.  During  the  manual  control  mode  the  manual  control  buttons(“11 

and 12”  from control panel guide) will be activated. 

5.  Pressing  the  In/Out  button  (“12”    from  control  panel  guide)  will 

control the platform movement.  

6.  Pressing the UP/Down  button (“11”  from control panel guide) will 

control the Hot Bar Tool movement.  

7.  The Platform can only be controlled when the Hot bar tool is at the 

up position. 

6. 

EMERGENCY STOP BUTTON 

1.  In case of immediate requirement to stop the automated soldering 

cycle  the  Emergency  Stop  Button  can  be  pushed.  (“15”    from 

control panel guide)  

2.  When emergency stop button is engaged the hot bar soldering tool 

would move to the “up” position while the platform would move into 

the  “in”  position.  The  system  would  be  locked  to  manual  control 

mode. 

3.  The Platform and hot bar tool can then be manually adjusted to the 

adequate position. 

4.  To  disengage  Emergency  stop  mode  ,  unlock  the  Emergency  stop 

button by turning it clockwise. 

OPERATING GUIDELINES 

Summary of Contents for 8011

Page 1: ...o C Description Constant display of below 60o C temperature from the panel then displays Err on the panel after a few minutes SOLUTION Turn OFF unit and then ON again If Display still shows Err then the Heating element may be broken and needs to be replaced PROBLEM 4 DISPLAY PANEL SHOWS UNRECOGNIZABLE CHARACTERS SOLUTION Switch unit OFF wait a few seconds and ON again If problem persists contact v...

Page 2: ...ic or Manual Control can be selected by pressing the SELECT button 10 from control panel guide 2 When the RED Lamp is lighted it means the system is currently in Manual control mode 3 If the Green Lamp is lighted the system is in automatic control mode push the SELECT button to switch to manual control mode 4 During the manual control mode the manual control buttons 11 and 12 from control panel gu...

Page 3: ...N Improper usage can cause serious injury to personnel and or damage to equipment For personnel safety please follow these precautions Check each component after opening the package to make sure everything is in good condition Do not use item if visible damage is seen report the issue to your vendor Power off unit and unplug the device when moving the device from one loca tion to another Do not su...

Page 4: ...N the main power switch Located at the back of the unit 3 Display panels 6 and 8 will display C100 and 0010 default parameters 2 ADJUSTING PRESSURE 1 Adjust to desire pressure level using the Air pressure control Knob 1 from control panel guide Pull on the knob to unlock it before adjusting pressure level Push knob back in to lock into place 2 If Higher pressure is needed the pressure control knob...

Reviews: