IMPORTANT: 

Never allow temperature setting above 300 degrees Celsius 

for pro-longed period. Temperature setting at lower temperature will 

preserve heater life.

 

5. 

The Timer can be adjusted  by pushing the “+” and “-” buttons of 

the Timer control buttons.  (“9”  from control panel guide).  

6. 

The  Timer  display  (“8”    from  control  panel  guide)    will  show  the 

current set timer settings. 

7. 

Timer  settings  can  only  be  adjusted  during  automated  control 

mode. 

Note: The Set Temperature and Timer settings will automatically be saved 

into the CPU memory once one complete cycle of the automated 

procedure is finished.  

4. 

AUTOMATIC CONTROL  

1. 

Automatic  or  Manual  Control  can  be  selected  by  pressing  the 

SELECT button. (“10”  from control panel guide).  

2. 

When the Green Lamp is lighted it means the system is currently 

in Automatic control mode. 

3. 

If the Red Lamp is lighted the system is in manual control mode, 

push the SELECT button to switch to automatic control mode. 

4. 

To  initiate  the  automatic  soldering  procedure  push  both  start 

buttons simultaneously (“13,16”  from control panel guide). 

 

5.    The automatic soldering cycle: 

● 

The platform moves in 

● 

If  platform  is  completely  in,  the  hot  bar  soldering  tool  would 

descend. 

● 

When the  hot bar soldering tool has reached the platform count

 

down timer would commence. 

● 

With Count down completed, hot bar tool would move back up. 

● 

The platform slides out to original position. 

6. 

The automatic soldering  cycle can be repeated by pressing both 

start buttons again. 

OPERATING GUIDELINES 

3

33

  

  

  

 

 

CAUTION: Improper usage can cause serious injury to personnel and/or damage 

to equipment. For personnel safety, please follow these precautions:

 

● 

Check each component after  opening the  package to make sure everything 

is  in  good  condition.  Do  not  use  item  if  visible  damage  is  seen,  report  the 

issue to your vendor. 

● 

Power off unit and unplug the device when moving the device from one loca-

tion to another. 

● 

Do not subject the main unit to physical shock 

     - Never drop or sharply jolt the unit. 

     - Contains delicate parts that may break if the unit is dropped. 

● 

Always connect power to a grounded receptacle. 

● 

Tip temperature may reach as high as 350°C when switched ON. 

● 

Disconnect from power source if the unit will not be used for a long periods.  

● 

Use only genuine replacement parts. 

● 

Soldering process produces smoke — use on well ventilated place. 

● 

Do not try to alter or repair unit, bring to qualified service center for repairs. 

● 

Never insert body parts between the paths of the moving platforms. 

1. 

Place unit on top of a flat and stable work table. 

2. 

LCD  Monitor 

— Pull out the LCD Monitor mounting bracket on each 

side of the unit. Mount both LCD monitors.  Attach the 5 pin LCD moni-

tor connectors to the base of the  upper control box  and its other ends 

to the LCD monitor. 

3. 

Air  compressor** 

— Attach Air compressor tube to the unit. Turn 

off the main valve at the air compressor. Switch on the air compressor 

when   gauge at the air compressor reaches  0.2 MPA turn on the main 

valve. 

4. 

Make sure power switch is turned OFF before plugging the device to 

the main power source.  

Note: 

In  order  for  pneumatic  system  to  function,  Compressed  air  should 

be fed into system.    ** 

Air compressor is sold separately.

 

SAFETY PRECAUTIONS 

Initial Setup 

Summary of Contents for 8011

Page 1: ...o C Description Constant display of below 60o C temperature from the panel then displays Err on the panel after a few minutes SOLUTION Turn OFF unit and then ON again If Display still shows Err then the Heating element may be broken and needs to be replaced PROBLEM 4 DISPLAY PANEL SHOWS UNRECOGNIZABLE CHARACTERS SOLUTION Switch unit OFF wait a few seconds and ON again If problem persists contact v...

Page 2: ...ic or Manual Control can be selected by pressing the SELECT button 10 from control panel guide 2 When the RED Lamp is lighted it means the system is currently in Manual control mode 3 If the Green Lamp is lighted the system is in automatic control mode push the SELECT button to switch to manual control mode 4 During the manual control mode the manual control buttons 11 and 12 from control panel gu...

Page 3: ...N Improper usage can cause serious injury to personnel and or damage to equipment For personnel safety please follow these precautions Check each component after opening the package to make sure everything is in good condition Do not use item if visible damage is seen report the issue to your vendor Power off unit and unplug the device when moving the device from one loca tion to another Do not su...

Page 4: ...N the main power switch Located at the back of the unit 3 Display panels 6 and 8 will display C100 and 0010 default parameters 2 ADJUSTING PRESSURE 1 Adjust to desire pressure level using the Air pressure control Knob 1 from control panel guide Pull on the knob to unlock it before adjusting pressure level Push knob back in to lock into place 2 If Higher pressure is needed the pressure control knob...

Reviews: