User Manual AW5145W
www.aosong.com
Revision V1.0-May 2017
- 13 -
4. The transmitter supports both transit and broadcast modes. Using the transit mode, data
is uploaded directly to the server through the internet, then upper monitor software get the
data from sever to display. Using the broadcast mode, upper monitor software communicate
with the equipment directly in the LAN, not through the internet.
5. Transit mode related settings:
1) Set the transmitter remote address to 14.23.92.147 and remote port to 9002. In the
default situation, it is no need to modify.
2) Click on “New Device” button of the menu bar, and new device dialog box pop-up. Select
“TCP network”, “transit mode”, then enter the device access code and ID number. The
device access code is fixed to 12345678, and the device ID number can be obtained by
querying “device information”, and ID number is 24 bits. Click “OK” to add new device.
3) After the equipment added complete, click on the "start" button of the menu bar, and the