40
V = Visual command
Function
Read/Write
Command category
Type of command Parameter
Example
Response
PLOT MODE SET
W
V
PM
1=PAINT
2=OUTLINE
WVPM1 [CR]
+ or ?
PLOT MODE READ
R
V
PM
N/A
RVPM [CR]
VPM1 +
FDIR SET
W
V
DD
1=NORMAL
2=REVERSE
WVDD1 [CR]
+ or ?
FDIR READ
R
V
DD
N/A
RVDD [CR]
VDD1 +
LCD CONTRAST SET
W
V
CL
0 - 160
WVCL50 [CR]
+ or ?
LCD CONTRAST READ
R
V
CL
N/A
RVCL [CR]
VCL50 +
LCD DISPLAY MODE
W
V
RV
1=NORMAL
2=REVERSE
WVRV1 [CR]
+ or ?
LCD DISPLAY MODE
R
V
RV
N/A
RVRV [CR]
VRV1 +
SEND VISUAL IMAGE
R
V
IM
N/A
RVIM [CR]
VIM +
FOLLOWED BY
IMAGE AND +
U = User interface
Function
Read/Write
Command category
Type of command Parameter
Example
Response
RECEIVE MODE SET
W
U
MD
1=WFM
WUMD3 [CR]
+ or ?
2=NFM
3=AM
4= LSB
5=USB
6=CW
7=AUTO
RECEIVE MODE READ
R
U
MD
N/A
RUMD [CR
UMD3 +
ATTENUATOR SET
W
U
AT
1=ON
2=OFF
WUAT2 [CR]
+ or ?
ATTENUATOR READ
R
U
AT
1=ON
2=OFF
RUAT [CR]
UAT2 +
STEP SIZE SET
W
U
ST
SIZE IN kHz
WUST25 [CR]
+ or ?
STEP SIZE READ
R
U
ST
N/A
RUST [CR]
UST25.00 +
(FOR 25 kHz
STEP)
COMPANION RX SET
W
U
RX
1=AR5000
WURX1 [CR]
+ or ?
2=AR3000A
3=IC-R7100
4=IC-R8500
5=IC-R9000
6=OTHER
COMPANION RX READ
R
U
RX
N/A
RURX [CR]
URX1 +
MK-CF
W
U
MC
N/A
WUMC [CR]
+ or ?
STEP-UP
W
U
SU
N/A
WUSU [CR]
+ or ?
STEP-DOWN
W
U
SD
N/A
WUSD [CR]
+ or ?
Section 7