![AOpen OpenBook 1556 Service Manual Download Page 34](http://html.mh-extra.com/html/aopen/openbook-1556/openbook-1556_service-manual_2950740034.webp)
26
OpenBook 1556
AC Adapter
Item
Specification
Vendor & model name
Delta ADP-65DB
Input Requirements
Maximum input current (A, @90Vac,
full load)
1.5 A @ 90Vac
0.9 A @ 180Vac
Nominal frequency (Hz)
47 - 63
Frequency variation range (Hz)
47 - 63
Nominal voltages (Vrms)
90 - 270
Inrush current
The maximum inrush current will be less than 50A and 100A when the
adapter is connected to 100Vac(50Hz) and 240Vac(60Hz) respectively.
Efficiency
It should provide an efficiency of 85% minimum, when measured at
maximum load under 240V(60Hz).
Output Ratings (CV mode)
DC output voltage
+19.0V~21.5V
Noise + Ripple
300mvp-pmax (20MHz bandwidth)
Load
0 A (min.) 3.42 A (max.)
Output Ratings (CC mode)
DC output voltage
+12V ~ +19V
Constant output
4.5 ± 0.3 A
Dynamic Output Characteristics
Turn-on delay time
3 sec. (@100Vac)
Hold up time
6 ms min. (@100 Vac input, full load)
Over Voltage Protection (OVP)
25 V
Short circuit protection
Output can be shorted without damage (no broken, no smoke)
Electrostatic discharge (ESD)
15kV (at air discharge)
8kV (at contact discharge)
Dielectric Withstand Voltage
Primary to secondary
1500 Vac (or 2121 Vdc), 10 mA for 1 second
Leakage current
0.25 mA max. (@ 254 Vac, 60Hz)
Regulatory Requirements
Internal filter meets:
1. FCC class B requirements. (USA)
2. VDE 243/1991 class B requirements. (German)
3. CISPR 22 Class B requirements. (Scandinavia)
4. VCCI class II requirements. (Japan)
Summary of Contents for OpenBook 1556
Page 6: ...VI OpenBook 1556 ...
Page 57: ...Chapter 2 49 ...
Page 58: ...50 OpenBook 1556 ...
Page 90: ...82 OpenBook 1556 ...
Page 108: ...100 OpenBook 1556 OpenBook 1556 Exploded Diagram ...
Page 122: ...114 OpenBook 1556 ...
Page 124: ...116 OpenBook 1556 ...
Page 127: ...Chapter 3 119 V Video 22 Resolutions 22 Video controller 24 W Windows XP Environment Test 110 ...
Page 128: ...120 OpenBook 1556 ...