Table 6-1
The DIP switch SW7 selected for 1 battery connected with inverter
Parallel battery
Group
DIP Switch
120R_INV
120R M/S
1
—
000
2
or 001
2
ON
ON
The DIP switch SW7 selected for 2 batteries connected with inverter
Parallel batteries
Group
DIP Switch
120R_INV
120R M/S
2
Master
011
2
ON
ON
Slave
010
2
OFF
ON
The DIP switch SW7 selected for 3 batteries connected with inverter
Parallel batteries
Group
DIP Switch
120R_INV
120R M/S
3
Master
101
2
ON
ON
Slave 1
010
2
OFF
OFF
Slave 2
100
2
OFF
ON
The DIP switch SW7 selected for 4 batteries connected with inverter
Parallel batteries
Group
DIP Switch
120R_INV
120R M/S
4
Master
111
2
ON
ON
Slave 1
010
2
OFF
OFF
Slave 2
100
2
OFF
OFF
Slave 3
110
2
OFF
ON
Note
If two or more batteries connected with parallel mode, batteries need to be restarted.
6.4
Settings for CAN /485 bus pins
Confirm that the CANL/485B DIP switch is set to SW2 which pin is used for CAN
high signal by inverter (4-CANH/485A), and the CANL/485B DIP switch is set to
SW1 which pin is used for CAN low signal by inverter (5-CANL/485B).
As SW3 the CAN/485 GND DIP switch, installer should confirm which pin is used
for ground by inverter or not.