background image

bottom

case

terminal

blocks

E

L1

L2

control

board

flow meter

heating

chamber

temp. sensor

Fig 1

PG.3

ELECTRICAL DIAGRAM

PRODUCT INNER STRUCTURE

AC240V 60Hz

DISPLAY

SCREEN

INLET TEMP.SENSOR

OUTLET TEMP.SENSOR

FLOWMETER

THERMAL CUT-OUT 194°F

REMARK:   R:HEATING SYSTEM  T:TRIAC

CONTROL

SYSTEM

L1
L2

E

R

R

T

T

Summary of Contents for ENVO WH-AZ011-M2

Page 1: ...ITEM WH AZ011 M2 WH AZ146 M2 ANZZI ELECTRIC INSTANT WATER HEATER INSTALL OPERATION MANUAL V1 0 next page...

Page 2: ......

Page 3: ...enjoy your hot water life at its best please read and follow the installation and operation instructions carefully to ensure the long life and reliable operation of this appliance FAILURE TO DO SO CO...

Page 4: ...ons Electrical Diagram Product Inner Structure Product Specifications Installation Guideline Installation Operation Instructions Cleaning Maintenance Trouble Shooting Packing List PG 1 PG 3 PG 3 PG 4...

Page 5: ...o not operate the water heater again until it has been thoroughly checked by qualified service personnel When using electrical appliances basic safety precautions should always be followed including t...

Page 6: ...r listed above or other improper operations It is extremely important to FLUSH the pipes to wash away sundries and residue in the pipes before connecting the water heater to it Risk of Fire Hydrogen g...

Page 7: ...low meter heating chamber temp sensor Fig 1 PG 3 ELECTRICAL DIAGRAM PRODUCT INNER STRUCTURE AC240V 60Hz DISPLAY SCREEN INLET TEMP SENSOR OUTLET TEMP SENSOR FLOWMETER THERMAL CUT OUT 194 F REMARK R HEA...

Page 8: ...gh levels of minerals and alkali can cause damage to this unit Water softening system is needed for this case Voltage 240V 240V Wattage 11000W 14600W Rated Current 47 8A 60 83A Min required circuit br...

Page 9: ...fficient conduction for a ground Nonmetallic piping dielectric unions flexible connectors etc can cause the water heater to be electrically isolated Do not disconnect factory ground It is recommended...

Page 10: ...y saving or other unapproved devices other than those authorized by ENVO into onto or in conjunction with the water heater The use of unauthorized energy saving devices may shorten the life of the wat...

Page 11: ...on position for the water heater 2 Place template provided on wall and use pencil to mark screw hole locations Make sure the outlet and inlet pointed downward vertically If screw locations are in wall...

Page 12: ...hread protectors 1 2 ATTENTION Connect the inlet cold water line to the cold inlet fitting on water heater Connect the outlet hot water line to the hot outlet fitting on water heater Use two wrenches...

Page 13: ...uit 2 Connect the cable to the breaker Install L1 red wire to L1 L2 black wire to L2 and E green yellow wire to Ground Make sure that the metal wire ends and the breaker are well connected Then tighte...

Page 14: ...will remember and save the previously used temperature on the next use 7 There is an over temperature protection system for this unit When the temperature reaches 149 F 65 C the system will automatic...

Page 15: ...d another wrench to tighten the connecting pipes SYMPTOMS POSSIBLE CAUSES RECOMMENDED ACTIONS Inlet and outlet fittings leaking LED no signal Water too hot Water too cold LED shows E1 LED shows E3 Out...

Page 16: ......