background image

WARNING

Use stainless steel flexible hoses or copper 

tubes of 1/2” on the inlet and outlet. 
DO NOT USE PVC, CPVC or plastic supply 
line directly to the heater.

This appliance is forbidden to be switched 

on if you think it may be frozen, as this could 
result in serious damage to the unit. Wait until 
you are sure that it has completely thawed out 
before you switch it on.

This appliance is not intended for use by 

persons (include children) with reduced physical 
sensory or mental capabilities, or lack of 
experience and knowledge, unless under careful 
supervision. Children should be supervised to 
ensure that they do not play with the appliance.

Safety and energy conservation are factors to 

be considered when selecting the water 
temperature setting of water heater’s thermostat. 
Water temperatures above the 125°F (52°C) can 
cause severe burns from scalding.

DO NOT store or use gasoline or other 

flammable vapors and liquids in the vicinity of 
this or any other appliance. Keep rags and other 
combustibles away. 

If the water heater has been subjected to flood, 

fire, or physical damage, turn off power and water 
to the water heater. Do not operate the water 
heater again until it has been thoroughly checked 
by qualified service personnel. 

When using electrical appliances, basic 

safety precautions should always be 

followed including the following:

The installation must be in compliance with 

the National Electrical Code

, your local 

electrical and plumbing codes. 

This appliance must be 

GROUNDED. 

CONNECTED ONLY TO A CIRCUIT THAT IS 
PROTECTED BY A RECOGNIZED GROUND-
FAULT CIRCUIT INTERRUPTER(GFCI).

We highly recommend that you employ the 

services of a professional to assist you with 
this installation if you are not familiar with 
basic plumbing and electricity. Under no 
circumstances should you attempt to install, 
repair or disassemble the water heater 
without first disconnecting the electricity.

Install or locate this water heater only in 

accordance with the provided installation 
instructions. 

Use this water heater only for its intended 

use as described in this manual.

This appliance MUST be permanently 

connected to the fixed circuit breaker and it 
must be installed vertically. DO NOT install 
near tinder or a strong magnetic field.

SWITCH OFF the breaker before removing 

the cover for servicing.

If there is damage to the wire, you must 

contact qualified electrician to replace it with 
dedicated wire from our authorized dealers.

PG.1

SAFETY PRECAUTIONS

Summary of Contents for ENVO WH-AZ011-M2

Page 1: ...ITEM WH AZ011 M2 WH AZ146 M2 ANZZI ELECTRIC INSTANT WATER HEATER INSTALL OPERATION MANUAL V1 0 next page...

Page 2: ......

Page 3: ...enjoy your hot water life at its best please read and follow the installation and operation instructions carefully to ensure the long life and reliable operation of this appliance FAILURE TO DO SO CO...

Page 4: ...ons Electrical Diagram Product Inner Structure Product Specifications Installation Guideline Installation Operation Instructions Cleaning Maintenance Trouble Shooting Packing List PG 1 PG 3 PG 3 PG 4...

Page 5: ...o not operate the water heater again until it has been thoroughly checked by qualified service personnel When using electrical appliances basic safety precautions should always be followed including t...

Page 6: ...r listed above or other improper operations It is extremely important to FLUSH the pipes to wash away sundries and residue in the pipes before connecting the water heater to it Risk of Fire Hydrogen g...

Page 7: ...low meter heating chamber temp sensor Fig 1 PG 3 ELECTRICAL DIAGRAM PRODUCT INNER STRUCTURE AC240V 60Hz DISPLAY SCREEN INLET TEMP SENSOR OUTLET TEMP SENSOR FLOWMETER THERMAL CUT OUT 194 F REMARK R HEA...

Page 8: ...gh levels of minerals and alkali can cause damage to this unit Water softening system is needed for this case Voltage 240V 240V Wattage 11000W 14600W Rated Current 47 8A 60 83A Min required circuit br...

Page 9: ...fficient conduction for a ground Nonmetallic piping dielectric unions flexible connectors etc can cause the water heater to be electrically isolated Do not disconnect factory ground It is recommended...

Page 10: ...y saving or other unapproved devices other than those authorized by ENVO into onto or in conjunction with the water heater The use of unauthorized energy saving devices may shorten the life of the wat...

Page 11: ...on position for the water heater 2 Place template provided on wall and use pencil to mark screw hole locations Make sure the outlet and inlet pointed downward vertically If screw locations are in wall...

Page 12: ...hread protectors 1 2 ATTENTION Connect the inlet cold water line to the cold inlet fitting on water heater Connect the outlet hot water line to the hot outlet fitting on water heater Use two wrenches...

Page 13: ...uit 2 Connect the cable to the breaker Install L1 red wire to L1 L2 black wire to L2 and E green yellow wire to Ground Make sure that the metal wire ends and the breaker are well connected Then tighte...

Page 14: ...will remember and save the previously used temperature on the next use 7 There is an over temperature protection system for this unit When the temperature reaches 149 F 65 C the system will automatic...

Page 15: ...d another wrench to tighten the connecting pipes SYMPTOMS POSSIBLE CAUSES RECOMMENDED ACTIONS Inlet and outlet fittings leaking LED no signal Water too hot Water too cold LED shows E1 LED shows E3 Out...

Page 16: ......