background image

AnyWireASLINK System Products Guide

ASLINKSENSOR [ASLINK Sensor]

BS-K4117-M

□□

-1K

[Notes on Safety]

A WARNING indicates a potentially hazardous situation which, if not 
handled correctly, could result in death or serious injury.

A CAUTION indicates a potentially hazardous situation which, if not 
handled correctly, may result in personal injury or property damage.

[Warranty]

CAUTION

WARNING

CAUTION

WARNING

Precautions that must be observed in order to use this system safely are 
indicated as shown below. You must observe these precautions.

 Warranty period

The warranty on the delivered Product shall continue to be effective for one (1) 
year after the delivery thereof to a location as designated by the original owner.

 Scope of warranty

Should a defect occur in any part of the Product during the foregoing warranty 
period when it is used normally in accordance with the specifications described 
in this User's Manual, the Company shall replace or repair the defect free of 
charge, except when it arises as a result of:
[1] Misuse or abuse of the Product by the owner; 
[2] Fault caused by cause other than the delivered Product;
[3] Unauthorized modification or repair of the Product by any party other than 

the Company;

[4] Any unusual force of nature, disaster, or other cause beyond the Company's 

control.

The term "warranty," as used herein, refers to the warranty applicable to the 
delivered product alone. The Company shall not be liable for any damages 
consequential or incidental to a malfunction of the delivered product.

 Repair at cost

After the expiration of the warranty period, any troubleshooting or repairs shall 
be done at the expense of the owner.
Even during the warranty term, any repairs and troubleshooting for defects 
arising from causes outside the scope of the warranty as specified above shall 
be done at the owner's expense.

 System Safety

This system is intended for general industrial applications. It does not 
have functions for supporting applications requiring higher levels of safety 
such as safety-related devices or accident prevention systems.

 Always turn off the system power before attempting to mount or replace.

 Prolonged continuous flow of a rated load current or higher or a transit 

current due to load short-circuit or similar problem, in the hybrid unit 
including the output unit and the output circuit may result in smoke 
generation or fire. An external safety device such as a fuse must be 
installed.

 System power supply

Use a stabilized 24V DC power supply. Use of a non-stabilized power 
supply may cause problems with the system.

 Separately route high-voltage and power cables

Although the AnyWireASLINK has a high noise margin, lay the 
transmission lines and I/O cables so as to keep them away from 
high-voltage and power cables.

 Connectors and terminals

 Pay careful attention to the length and installation of cable wiring to 

ensure that connectors and cables are neither stressed nor 
disconnected even if they are stressed.

 Make sure to prevent any metal objects from getting inside the 

connectors or the terminal blocks.

 Short-circuits caused by metal objects or mis-wiring are likely to 

damage the device.

 Do not impose any external loads on the units.

Doing so may cause a failure.

 Do not disconnect or reconnect between the transmission line and slave 

units when a transmission line is operating.
A malfunction may occur.

 Use the AnyWireASLINK within the range of the specifications and 

conditions shown below.

[Type]

ASLINKSENSOR two-wire (non-isolated) terminal
Electromagnetic induction type
Sensitivity adjustment value (Threshold)
Hysteresis
Alarm judgment value
Alarm judgment time
Normally open/Normally close
Delay timer
Slave unit voltage drop
Sensing level drop
Teaching abnormality

Detection method

Model

Functions

READER/WRITER

ARW-04

Ver.04-1.01

LotNo.***

MADE IN JAPAN

"Ver.*.**" is 

written on 

this label.

The version is 

displayed when 

the power is 

turned on.

Front

Rear

ARW-04

-BSK4117M**1K  1/9-

Transmission cable

(Oil-resistant, flex-resistant type)

DP (red)

DN (black)

LINK display
IN display
ALM display
Setting port

Detection surface

Full thread

Toothed washer

 Example for  BS-K4117-M18-1K

[Function]

[Included items]

[Name of each part]

BS-K4117-M12-1K

M12, black nickel plating

BS-K4117-M18-1K

M18, black nickel plating

BS-K4117-M30-1K

M30, black nickel plating

AnyWireASLINK proximity sensor: Amplifier-embodied type, 
 

all metal detection type

This product...1
Nut...2
Toothed washer...1

BS-K4117-M12-1K

BS-K4117-M30-1K

BS-K4117-M18-1K

* If mounting clamps are required, please purchase them separately.
* Setting of addresses in this product requires the "address writer ARW-04 

(Ver.04-1.01 or higher) or ARW-03 (Ver.2.10 or higher)."  Prepare that as well.

Summary of Contents for ASLINKSENSOR BS-K4117-M 1K Series

Page 1: ...circuit or similar problem in the hybrid unit including the output unit and the output circuit may result in smoke generation or fire An external safety device such as a fuse must be installed System power supply Use a stabilized 24V DC power supply Use of a non stabilized power supply may cause problems with the system Separately route high voltage and power cables Although the AnyWireASLINK has ...

Page 2: ...for the AnyWireASLINK according to the load current This Products Guide describes a two wire non isolated terminal If the load current is small using a two wire non isolated terminal allows for achieving simplified wiring without a local power supply If you are prioritizing the sites of concentrated loads or the number of units connected hybridization with a four wire isolated terminal which suppo...

Page 3: ... EAC 06 472 MAX 6A 24V DC Model Type Allowable power current Filter allowable power current Insert the ASLINK filter Type ANF 01 regardless of installation method and distance when complying with CE Standard General purpose power supply filter Use if necessary General purpose power supply filter Use if necessary POWER IN SLAVE The figure is an explanatory schematic Adjust the actual terminal layou...

Page 4: ...re terminal Four wire terminal DP DN 24V 0V Four wire terminal Four wire terminal DP DN 24V 0V Four wire terminal DP DN 24V 0V Four wire terminal 24V 0V 24V 0V PE AnyWireASLINK master 24V 0V L N FG 24V DC stabilized power supply 24V 0V 24V 0V PE DP DN 24V 0V Four wire terminal DP DN 24V 0V Four wire terminal A B General purpose power supply filter Use if necessary General purpose power supply filt...

Page 5: ...and then hitch the hook C to fix the cover Insert the body clamp into the hole of the cover and crimp them with a dedicated tool For the LP4 WW 10P perform crimping with pin 1 for DN pin 2 for DP and pins 3 and 4 empty After crimping check that the hooks to are securely engaged With cover mounted Check that the hooks and are engaged Installation Location Precautions for Use If you expect you will ...

Page 6: ...etting is changed in the WRITE mode the setting is reflected after the system is re started up When setting is changed in the DIRECT WRITE mode the setting is reflected at the time when the writing is completed If this unit is included in a parallel arrangement use the remote head ARW RH together and ensure that writing is not performed to terminals not intended Make sure to use a 24V DC stabilize...

Page 7: ...timer ON delay timer enabled OFF delay timer enabled Address writer ARW 04 ARW 03 Parameter 10 Default 0 Set the ON delay timer OFF delay timer 0 255 Default 0 Address writer ARW 04 ARW 03 Parameter 11 Normally open Normally close setting Variable Details 0 Normally open ON with work present Set the normally open normally close 1 Normally close ON with work absent Alarm value Hi setting Alarm valu...

Page 8: ...as shown below ASLINKSENSOR is not connected to an AnyWireASLINK system Power supply for the AnyWireASLINK system itself is not turned on Directly connected to 24 0V power supply The ASLINKSENSOR maintains the address number 255 default setting The ASLINKSENSOR has an address redundant with another unit Transmission signal level reduction has been detected The sensing level has been reduced Confir...

Page 9: ...2017 UMA 16717A EN Outside Dimensions Unit mm BS K4117 M18 1K BS K4117 M12 1K BS K4117 M30 1K Transmission cable Oil resistant flex resistant type φ29 24 1000 15 5 35 4 10 17 M18X1 Red DP Black DN Transmission cable Oil resistant flex resistant type Red DP Black DN φ21 17 35 5 3 10 15 4 1000 11 M12X1 10 5 Red DP Black DN M30X1 5 43 36 φ42 17 6 1000 Transmission cable Oil resistant flex resistant t...

Reviews: