![Anywave TSP-EAS-1 User Manual Download Page 25](http://html1.mh-extra.com/html/anywave/tsp-eas-1/tsp-eas-1_user-manual_2949017025.webp)
TSP-EAS-1 User Manual
Version 1.6 5/10/2017
Page 25 of 30
LCD:
ASIOUT# N/A
Cause: There is not valid TS in ASI input, or user has not selected a program to be muxed into the
ASI output
Solution: Check stream of ASI input, and make sure programs are selected correctly in the control
GUI.
ASI Output Overflow
Alarm message
GUI:
Overflow RED
Cause: Payload exceeds the total TS rate.
Solution: Check the selection of programs to be multiplexed, reduce the number of programs
selected.
5.5 DPSIP
DPSIP ERROR
Alarm message
LCD:
PSIP STATUS ERR
LED_STAT
ON
Cause: MUX didn’t detect the input Dynamic PSIP data.
Solution: Check the configuration of PSIP Generator, reboot Dynamic PSIP module if needed.
DPSIP Overflow
Alarm message
LED_STAT:
FLASHING
GUI:
Overflow YES
Cause: Dynamic PSIP data rate exceeds bandwidth set for PSIP data.
Solution: Check the PSIP Generator’s output data rate, set PSIP bandwidth greater than data rate
reported by PSIP Generator.