![Anybus Wireless Bridge II User Manual Download Page 15](http://html1.mh-extra.com/html/anybus/wireless-bridge-ii/wireless-bridge-ii_user-manual_2948750015.webp)
13 (38)
4.3.2
Easy Config
Fig. 5
Easy Config page
To activate an Easy Config mode, select it from the dropdown menu and click on
Set
.
Easy Config Modes
Mode Role
Description
LED
2
—
Reset configuration to factory defaults.
B
3
—
Reset IP settings to factory defaults.
A
B
4
Client
Wait for automatic configuration.
C
5
WLAN AP
Configure units in mode 4 as clients.
Restart as access point and connect clients.
A
C
6
Bluetooth NAP
B
C
7
WLAN AP
Configure units in mode 4 as clients.
Restart as access point and connect clients.
Apply PROFINET optimizations to all units.
A
B
C
8
Bluetooth NAP
D
10
—
Apply PROFINET optimizations and restart.
B
D
Modes 5, 6, 7 and 8 will scan for units in mode 4. The detected units will be reconfigured as
clients, while the scanning unit will restart as an access point. The clients will then restart and
connect to the access point.
Modes 7 and 8 will additionally apply PROFINET optimization to all the units. PROFINET
messages will then have priority over TCP/IP frames.
Mode Timeout
•
Modes 5, 6, 7 and 8 will time out after 120 seconds. Reapply the mode to repeat the scan.
•
Mode 4 will listen for 120 seconds or until receiving a configuration.
The IP address of a client may be changed by the configuration from the access
point. Active browser sessions could therefore be lost.