36 (70)
Instance Attributes (Instance #21, Process active timeout)
This instance holds the settings for the Process active timeout. Changes have immediate effect. See
for more information.
#
Name
Access
Data Type
Description
1
Name
Get
Array of
CHAR
“Process tmo”
(Multilingual, see page
)
2
Data type
Get
UINT8
05h (= uint16)
3
Number of elements
Get
UINT8
01h (one element)
4
Descriptor
Get
UINT8
07h (read/write/shared access)
5
Value
Get/Set
UINT16
Default = 0 (milliseconds, disable timeout)
6
Configured Value
Get
UINT16
Holds the configured value, which will be written to attribute #5.
Default = 0 (milliseconds, disable timeout)
Instance Attributes (Instance #22, Word order)
This instance holds the Word order settings. Value is used after module reset.
#
Name
Access
Data Type
Description
1
Name
Get
Array of
CHAR
“Word order”
(Multilingual, see page
)
2
Data type
Get
UINT8
04h (= UINT8)
3
Number of elements
Get
UINT8
01h (one element)
4
Descriptor
Get
UINT8
07h (read/write/shared access)
5
Value
Get/Set
UINT8
Value:
0
1
Meaning:
Little endian (default)
Big endian
Other values will be translated to 0 (default).
6
Configured Value
Get
UINT8
Holds the configured value, which will be written to attribute #5.
Value:
0
1
Meaning:
Little endian (default)
Big endian
Other values will be translated to 0 (default).
Anybus
®
CompactCom
™
40 Modbus-TCP
®
Transparent Ethernet Network Guide
SCM-1202-022 1.1